Summary for Test 2026-09-19-25-1
Test performed: AASHTO T308-25Project Information
| Project Identifiers | Project ID: 1000607 DEA: 081K6904 EFIS: 0819000090 |
|---|---|
| DIST-CO-RTE-PM | 08-RIV-74-5.7/11.8 |
| Award Date | 01/09/2025 |
| Closeout Date | Not set |
| Work Description | ROCK EXCAVATION, HMA (TYPE A), RHMA-G, AND CABLE NET DRAPERY SYSTEM. |
| Location Description | RIVERSIDE COUNTY IN AND NEAR LAKE ELSINORE FROM MONTE VISTA STREET TO GRAND AVENUE |
| QA Service Level | 1 (Verified on 01/13/2025) |
Sample Information
| Sample Taken Date | 09/19/2026 | Sample Unique Key | 25 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 09/23/2026 | Sample type | Acceptance |
| A brief description of the sample | 3/4" HMA-A | The quantity of what the sample constitutes | 4 BOXES, LOAD #53, TONS 903.72 |
| From where was the sample collected | Supplier | First name of sampler or witnessed by | MARYANNA |
| Last name of sampler or witnessed by | LANDAVERDE | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | 0574A-26 | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | MARTIN MARIETTA LAKE ELSINORE | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | |
| Sublot number | HMA Mix Number | 53417105 | |
| Binder content (%) | 5.0 | Virgin binder PG | PG 64-10 |
| Design binder PG | Binder Supplier | VALERO | |
| RAP content (%) | 25 | WMA Additives | No |
| Antistrip type | 0.5% INGEVITY EVOTHERM |
Test Details
DIME Sample ID: 2026-09-19-25
DIME Test ID: 2026-09-19-25-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T308-25: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2026-09-29
Test Results
What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: Elias Hamel
Date of test: 09/24/2026
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 2248.3 g
Mass Loss: 127.9 g
Correction Factor (Percent by mass of HMA Specimen): 0.75 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.13 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 4.81 %
General comments (publicly viewable) (Max 1000 characters): OVEN #2
RANGE 4.70-5.50
Test was verified on 9/29/2026 ✔