Summary for Test 2026-09-03-2-1

Test performed: ASTM A416-18

Project Information

Project IdentifiersProject ID: 1000710
DEA: 100P9244
EFIS: 1023000226
DIST-CO-RTE-PM10-MPA-140-42.0/42.7
Award Date08/22/2025
Closeout DateNot set
Work DescriptionFergusen Slide Rock Avalanche Shed
Location DescriptionMariposa County, along Route 140 in the Merced River canyon, about 8 miles east of Briceburg and 7.6 miles west of El Portal.
QA Service Level1 (Verified on 10/15/2024)

Sample Information

Sample Taken Date09/03/2026 Sample Unique Key2
Date that the sample was received by the laboratory/organization performing the testing09/15/2026 Sample typeQuality Assurance
A brief description of the samplebare strand The quantity of what the sample constitutes5
From where was the sample collectedFabricator First name of sampler or witnessed byEdward
Last name of sampler or witnessed byLeach Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameSumiden Wire
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM4 - Prestressing Strand Comments
Reel/Coil/Pack Number(s)T350461-2, T350461-3, T350461-4, T350461-5, T350461-7 Number of Coils5
Group Number Strand Diameter.6 in
Grade270 Strand SpecificationASTM A 416
Heat Number(s)T1383508 Mfg. Lot Number(s)n/a
Manufacturer(s)Sumiden Wire

Test Details

DIME Sample ID: 2026-09-03-2
DIME Test ID: 2026-09-03-2-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A416-18: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Test Release Date: 2026-09-28

Test Results


Number of Samples: 10
Input Type: Measured
Tester's full name: Steven Paine
Date of test: 09/28/2026
UTM: NA
Temperature: 0 f
Extensometers: NA
NumHeat NumberCoilArea (sqin)Peak Load (lbf)Load at EUL (lbf)Chord Modulus (Msi)Elongation (in)Tested By
1T1383508T350461-20.217589205380026.96.9Atlas
2T1383508T350461-20.2175972052930289.3Atlas
3T1383508T350461-30.217596705414026.36.67Atlas
4T1383508T350461-30.217591205473028.66.9Atlas
5T1383508T350461-40.2175972054260286.9Atlas
6T1383508T350461-40.217597105432028.26.9Atlas
7T1383508T350461-50.217601005358026.76.8Atlas
8T1383508T350461-50.217592205547029.47.2Atlas
9T1383508T350461-70.217589705407027.26.9Atlas
10T1383508T350461-70.217589255299532.46.9Atlas

General comments (publicly viewable) (Max 1000 characters):

Test was verified on 9/28/2026 ✔