Summary for Test 2026-09-15-72-5

Test performed: AASHTO T316-22

Project Information

Project IdentifiersProject ID: 1001156
DEA: 081L9104
EFIS: 0821000038
COOP: 081734
DIST-CO-RTE-PM08-SBD-38-51.9
Award Date12/17/2024
Closeout DateNot set
Work DescriptionState Highway 38 at Stanfield Cutoff Roundabout
Location DescriptionIntersection of Stanfield Cutoff and State Highway 38 in the Big Bear area
QA Service Level2 (Verified on 04/07/2025)

Sample Information

Sample Taken Date09/15/2026 Sample Unique Key72
Date that the sample was received by the laboratory/organization performing the testing09/16/2026 Sample typeVerification
A brief description of the sampleAsphalt Binder Sample The quantity of what the sample constitutes1can
From where was the sample collectedSource First name of sampler or witnessed byRobert
Last name of sampler or witnessed byJardine Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameVulcan-Oro Grande
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAsphalt Binder Performance GradePG 58-22
Modified Lot number
Sublot number Tank number
Time of sample HMA Suppliern/a
Certified Asphalt SupplierValero Wilmington Refinery - Wilmington CA MultigradeNo
Multigrade Type Asphalt Binder Mix Number
HMA Typen/a HMA Supplier Mix ID Numbern/a

Test Details

DIME Sample ID: 2026-09-15-72
DIME Test ID: 2026-09-15-72-5
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T316-22: Standard Method of Test for Viscosity Determination of Asphalt Binder Using Rotational Viscometer
Test Release Date: 2026-10-13

Test Results


Is viscosity reading in cP/Pa-s?: Pa-s
Input Type: Measured
Tester's full name: Hussaya Leelakitrungruang
Date of test: 09/24/2026
Time of test: 9:13 HH:MM
Test Temperature: 135.0 C
Speed: 100 rpm
Spindle size: 21 in
Torque: 45.5 %
Viscosity reading #1 (A) : 0.226 Pa-s
Viscosity reading #2 (B) : 0.228 Pa-s
Viscosity reading #3 (C): 0.23 Pa-s
Average viscosity: 0.228 Pa-s
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 10/13/2026 ✔