Summary for Test 2026-08-23-24-6
Test performed: AASHTO T269-14Project Information
| Project Identifiers | Project ID: 1001683 DEA: 040AA194 EFIS: 0419000450 |
|---|---|
| DIST-CO-RTE-PM | 04-CC-4-R29.0/R44.4 |
| Award Date | 01/09/2026 |
| Closeout Date | Not set |
| Work Description | COLD PLANE AC PVMT, RHMA-G & HMA OVERLAY, REPLACE AC SURF, & MGS. |
| Location Description | CONTRA COSTA COUNTY IN ANTIOCH AND AT BYRON FROM HILLCREST AVENUE OVERCROSSING TO BYRON HIGHWAY |
| QA Service Level | 1 (Verified on 10/06/2025) |
Sample Information
| Sample Taken Date | 08/23/2026 | Sample Unique Key | 24 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 08/24/2026 | Sample type | Quality Assurance |
| A brief description of the sample | 1/2" RHMA-G | The quantity of what the sample constitutes | 750 Tons |
| From where was the sample collected | Manufacturer | First name of sampler or witnessed by | Danny |
| Last name of sampler or witnessed by | Estrada | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Teichert Vernalis | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | RHMA-G |
|---|---|---|---|
| HMA Grading | 1/2 inch | Lot number | 5 |
| Sublot number | 4 | HMA Mix Number | |
| Binder content (%) | 0.0 | Virgin binder PG | |
| Design binder PG | Binder Supplier | ||
| RAP content (%) | Not set | WMA Additives | |
| Antistrip type |
Test Details
DIME Sample ID: 2026-08-23-24
DIME Test ID: 2026-08-23-24-6
Testing Lab: CT D04 - Concord Field Laboratory
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Test Release Date: 2026-09-25
Test Results
Number of tests: 3
Is the sample lab compacted or field compacted?: Field compacted
Input Type: Measured
Tester's full name: Anthony Valdez
Date of test: 08/25/2026
| 1 | 2 | 3 | ||||
|---|---|---|---|---|---|---|
| 2.233 | 2.218 | 2.184 | ||||
| 2.402 | ||||||
7.0 % | 7.7 % | 9.1 % | ||||
7.9 % | ||||||
92.1 % | ||||||
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 9/25/2026 ✔