Summary for Test 2026-09-23-30-1
Test performed: AASHTO T176-08Project Information
| Project Identifiers | Project ID: 1001246 DEA: 041Q7214 EFIS: 0423000277 |
|---|---|
| DIST-CO-RTE-PM | 04-CC,CC,SOL-580,680,780-Var |
| Award Date | 09/25/2025 |
| Closeout Date | Not set |
| Work Description | INSTALL FIBER OPTIC CABLE SYSTEM, RAMP METERING, AND WIDEN ROADWAY. |
| Location Description | ALAMEDA, CONTRA COSTA AND SOLANO COUNTIES AT VARIOUS LOCATIONS |
| QA Service Level | 1 (Verified on 08/13/2025) |
Sample Information
| Sample Taken Date | 09/23/2026 | Sample Unique Key | 30 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 09/24/2026 | Sample type | Production Start-Up |
| A brief description of the sample | 1/2"HMA w/25% RAP | The quantity of what the sample constitutes | 750 Tons |
| From where was the sample collected | Source | First name of sampler or witnessed by | Leo |
| Last name of sampler or witnessed by | Mendoza | Title of sampler | TET |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Vulcan Pleasanton Plant | |
| Transportation Laboratory (TL) Number | CPL092326 | Inspector Lot Number from the Transportation Laboratory (TL) Form | |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-01-0010 |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
| The plant number | A detailed description of where the material sample was collected | At the plant | |
| Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 1/2 inch | |
| The concrete mix design number | Lot number | ||
| Sublot number | Aggregate Mix Number |
Test Details
DIME Sample ID: 2026-09-23-30
DIME Test ID: 2026-09-23-30-1
Testing Lab: CT D04 - Pleasanton Field Laboratory
Test Method: AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)
Test Release Date: 2026-09-25
Test Results
How many times will the test be run?: 3 Times
Input Type: Measured
Tester's full name: Dennis Yeung
Date of test: 09/24/2026
Clay Level (Test 1): 6
Sand Level (Test 1): 3.8
Clay Level (Test 2): 6.1
Sand Level (Test 2): 3.9
Clay Level (Test 3): 6
Sand Level (Test 3): 3.8
Sand Equivalent (Test 1): 64
Sand Equivalent (Test 2): 64
Sand Equivalent (Test 3): 64
Sand Equivalent: 64
General comments (publicly viewable) (Max 1000 characters): 3 SE's and its average.
Test was verified on 9/25/2026 ✔