Summary for Test 2026-09-11-56-1

Test performed: CTM 521-June 2020

Project Information

Project IdentifiersProject ID: 1000511
DEA: 06487404
EFIS: 0616000029
DIST-CO-RTE-PM06-TUL-99-35.8/37.1
Award Date01/14/2025
Closeout DateNot set
Work DescriptionCaldwell Interchange SR99/Ave280 (Visalia) - Replace Bridge Structures and Construct Roundabouts.
Location DescriptionTULARE COUNTY IN AND NEAR VISALIA FROM 0.6 MILE SOUTH OF AVENUE 280 OVERCROSSING TO 0.7 MILE NORTH OF AVENUE 280 OVERCROSSING
QA Service Level1 (Verified on 08/27/2024)

Sample Information

Sample Taken Date09/11/2026 Sample Unique Key56
Date that the sample was received by the laboratory/organization performing the testing09/14/2026 Sample typeQuality Control
A brief description of the sampleTYPE II /V The quantity of what the sample constitutes9.50 CY
From where was the sample collectedJob Site First name of sampler or witnessed byJOEY
Last name of sampler or witnessed byBUCKLER Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameCEMEX -REDLANDS
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design number1610974
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected32136290
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedCONCRETE SAMPLE FROM WHEELBARROW Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2026-09-11-56
DIME Test ID: 2026-09-11-56-1
Testing Lab: Surecast West
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2026-09-25

Test Results


Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Calculated
Tester's full name: JOEY BUCKLER
Date of test: 09/23/2026
Capped in accordance with?: ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1: 4.00 in
Average diameter of cylinder 2: 4.00 in
Average diameter of cylinder 3: 4.00 in
Maximum load on cylinder 1: 69190 lb
Maximum load on cylinder 2: 67560 lb
Maximum load on cylinder 3: 68290 lb
Type of fracture pattern of cylinder 1: 1
Type of fracture pattern of cylinder 2: 1
Type of fracture pattern of cylinder 3: 1
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Correction factor for cylinder 3: 1.00
Age of specimen: 12 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 4 in^2
Cross sectional area of cylinder 2: 4 in^2
Cross sectional area of cylinder 3: 4 in^2
Compressive strength (to nearest 10 psi): 5440 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 9/25/2026 ✔