Summary for Test 2026-08-20-75-2
Test performed: AASHTO T176-08Project Information
| Project Identifiers | Project ID: 1001651 DEA: 11431004 EFIS: 1119000214 |
|---|---|
| DIST-CO-RTE-PM | 11-SD-5-R49.3/R53.2 |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | ADA CURB RAMPS AND REALIGNMENT OF MISSION AVE SB ON RAMP/NB OFF RAMP. |
| Location Description | SAN DIEGO COUNTY IN CARLSBAD AND OCEANSIDE FROM TAMARACK AVENUE OVERCROSSING TO MISSION AVENUE OVERCROSSING |
| QA Service Level | 1 (Verified on 10/01/2025) |
Sample Information
| Sample Taken Date | 08/20/2026 | Sample Unique Key | 75 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 08/19/2026 | Sample type | Production Start-Up |
| A brief description of the sample | PSU | The quantity of what the sample constitutes | 5 bags |
| From where was the sample collected | Supplier | First name of sampler or witnessed by | Mohammed |
| Last name of sampler or witnessed by | Masud | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Vulcan Escondido | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | See Mix |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
| The plant number | A detailed description of where the material sample was collected | Plant | |
| Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 3/4 inch | |
| The concrete mix design number | Lot number | ||
| Sublot number | Aggregate Mix Number | 220305 ESC VAL |
Test Details
DIME Sample ID: 2026-08-20-75
DIME Test ID: 2026-08-20-75-2
Testing Lab: CT D11 - District 11 Materials Laboratory
Test Method: AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)
Test Release Date: 2026-09-25
Test Results
How many times will the test be run?: 3 Times
Input Type: Measured
Tester's full name: Shawn Rivers
Date of test: 09/24/2026
Clay Level (Test 1): 5.4
Sand Level (Test 1): 3.9
Clay Level (Test 2): 5.7
Sand Level (Test 2): 4
Clay Level (Test 3): 5.5
Sand Level (Test 3): 3.9
Sand Equivalent (Test 1): 73
Sand Equivalent (Test 2): 71
Sand Equivalent (Test 3): 71
Sand Equivalent: 72
General comments (publicly viewable) (Max 1000 characters): Complies
Test was verified on 9/25/2026 ✔