Summary for Test 2026-07-17-9-2
Test performed: ASTM A416-18Project Information
| Project Identifiers | Project ID: 994675 DEA: 07390204 EFIS: 0722000334 |
|---|---|
| DIST-CO-RTE-PM | 07-LA-47-0.4 / 2.1 |
| Award Date | 01/24/2025 |
| Closeout Date | Not set |
| Work Description | Bridge deck replacement with lightweight precast deck panels ultra high performance concrete. Also includes: replacement of seismic sensors, upgrades to median barrier, railings, fences and guard rails. New finger joints. |
| Location Description | RTE 47 between Terminal Island and San Pedro PM 0.4/2.1 |
| QA Service Level | 1 (Verified on 08/07/2023) |
Sample Information
| Sample Taken Date | 07/17/2026 | Sample Unique Key | 9 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 12/22/2025 | Sample type | Quality Assurance |
| A brief description of the sample | 6/10" x 270 KSI PT Strand | The quantity of what the sample constitutes | 3 samples of two strands each |
| From where was the sample collected | Manufacturer | First name of sampler or witnessed by | Jamie |
| Last name of sampler or witnessed by | Doe | Title of sampler | Associate Steel Inspector |
| Telephone number of sampler | (916) 838-4405 | Laboratory sample identification | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Sumiden Wire | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | S50-048-26 | |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM4 - Prestressing Strand | Comments | |
|---|---|---|---|
| Reel/Coil/Pack Number(s) | S381076-9, S381092-9, S381109-9 | Number of Coils | |
| Group Number | Strand Diameter | .6 in | |
| Grade | 270 | Strand Specification | ASTM A 416 |
| Heat Number(s) | S0513526, S0253291, S0253980 | Mfg. Lot Number(s) | S381212-2, S381214-7, S381267-8 |
| Manufacturer(s) | Sumiden Wire |
Test Details
DIME Sample ID: 2026-07-17-9
DIME Test ID: 2026-07-17-9-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A416-18: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Test Release Date: 2026-09-24
Test Results
Number of Samples: 6
Input Type: Measured
Tester's full name: Steven Paine
Date of test: 09/24/2026
UTM: NA
Temperature: 0 f
Extensometers: NA
| Num | Heat Number | Coil | Area (sqin) | Peak Load (lbf) | Load at EUL (lbf) | Chord Modulus (Msi) | Elongation (in) | Tested By |
|---|---|---|---|---|---|---|---|---|
| 1 | S0513526 | S381212-2 | 0.217 | 63010 | 57090 | 0000 | 7.3 | RMA |
| 2 | S0513526 | S381212-2 | 0.217 | 58630 | 54820 | 0000 | 7.3 | RMA |
| 3 | S0253291 | S381214-7 | 0.217 | 58980 | 56990 | 0000 | 7.4 | RMA |
| 4 | S0253291 | S381214-7 | .0217 | 61500 | 54960 | 0000 | 7.4 | RMA |
| 5 | S0253980 | S381267-8 | 0.217 | 59460 | 55530 | 0000 | 6.0 | RMA |
| 6 | S0253980 | S381267-8 | 0.217 | 60150 | 53010 | 0000 | 7.3 | RMA |
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 9/24/2026 ✔