Summary for Test 2026-09-14-9-8
Test performed: ASTM B499-09r21Project Information
| Project Identifiers | Project ID: 994675 DEA: 07390204 EFIS: 0722000334 |
|---|---|
| DIST-CO-RTE-PM | 07-LA-47-0.4 / 2.1 |
| Award Date | 01/24/2025 |
| Closeout Date | Not set |
| Work Description | Bridge deck replacement with lightweight precast deck panels ultra high performance concrete. Also includes: replacement of seismic sensors, upgrades to median barrier, railings, fences and guard rails. New finger joints. |
| Location Description | RTE 47 between Terminal Island and San Pedro PM 0.4/2.1 |
| QA Service Level | 1 (Verified on 08/07/2023) |
Sample Information
| Sample Taken Date | 09/14/2026 | Sample Unique Key | 9 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 09/15/2026 | Sample type | Quality Assurance |
| A brief description of the sample | 7/8" x 2-3/4" F3125/F1852 A325TC Bolt Assembly | The quantity of what the sample constitutes | 9790 |
| From where was the sample collected | Job Site | First name of sampler or witnessed by | Johnathan |
| Last name of sampler or witnessed by | Shoulders | Title of sampler | Quailty Assurance Inspector |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Unytite Inc | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | 42220-1000225286 |
|---|---|---|---|
| Heat Number(s) | Bolt 1000225286 Nut 5806382906 Washer A81016 | Nut Mfg. Lot Number(s) | 41939-5806382906 |
| Washer Mfg. Lot Number(s) | 42138-A81016 | Bolt Specification | ASTM A325 |
| Bolt Length(s) | 2.75" | Nut Specification | ASTM F436 |
| Washer Specification | ASTM A563 | Finish | MECH Galv |
| Diameter/Size | 7/8" | Bolt Mfg. Lot Number | 42220-1000225286 |
| Rocap Test Requirement(s) | Yes | Lubricant Requirements(s) | Lub Nut |
| Washer Inner Diameter(s) | 875 in | Bolt Mill Supplier | Not set |
| Nut Mill Supplier | Not set | Washer Mill Supplier | Not set |
Test Details
DIME Sample ID: 2026-09-14-9
DIME Test ID: 2026-09-14-9-8
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Test Release Date: 2026-09-23
Test Results
Input Type: Calculated
Tester's full name: Steven Paine
Date of test: 09/23/2026
Sample No.: 1D
Rocap Number: no data
Heat Number(s): no data
Mfg. Lot Number: 42220-1000225286
Finish Coating: ASTM B695 - Mech Galv
Product Markings: no data
Size: .875 in
Bolt Length: 2.75 in
Measurement Average: 2.9 mils
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 9/23/2026 ✔