Summary for Test 2026-09-18-23-4
Test performed: AASHTO T275-07r12Project Information
| Project Identifiers | Project ID: 1002406 DEA: 09428804 EFIS: 0925000089 |
|---|---|
| DIST-CO-RTE-PM | 09-INY-395- |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | RTE 395 LITTLE LAKE PAVEMENT PRESERVATION (PM R8.4/R11.8): HMA (TYPE A) OVERLAY & DIGOUTS, HMA DIKE (TYPE E), SHOULDER BACKING, RUMBLE STRIP, FOG SEAL, COLD PLANE, THERMO STRIPING |
| Location Description | Not set |
| QA Service Level | 1 (Verified on 07/16/2026) |
Sample Information
| Sample Taken Date | 09/18/2026 | Sample Unique Key | 23 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 09/18/2026 | Sample type | Production Start-Up |
| A brief description of the sample | 3/4 HMA type A | The quantity of what the sample constitutes | 8 Boxes |
| From where was the sample collected | Source | First name of sampler or witnessed by | Bowman QC |
| Last name of sampler or witnessed by | Bowman QC | Title of sampler | QC |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Bowman Asphalt, Bakersfield | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | |
| Sublot number | HMA Mix Number | L261606 | |
| Binder content (%) | 0.0 | Virgin binder PG | |
| Design binder PG | Binder Supplier | ||
| RAP content (%) | Not set | WMA Additives | |
| Antistrip type |
Test Details
DIME Sample ID: 2026-09-18-23
DIME Test ID: 2026-09-18-23-4
Testing Lab: CT D09 - Bishop Field Laboratory
Test Method: AASHTO T275-07r12: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Paraffin-Coated Specimens (Bulk Specific Gravity)
Test Release Date: 2026-09-22
Test Results
Number of tests: 3
What test procedure is performed?: Method A
Input Type: Measured
Tester's full name: Derek Carrington
Date of test: 09/21/2026
| 1 | 2 | 3 | |
|---|---|---|---|
| 4698.2 g | 4699.1 g | 4698.8 g | |
| 4756.8 g | 4756.5 g | 4757.7 g | |
| 2731.4 g | 2728.9 g | 2730.5 g | |
| 0.9 | 0.9 | 0.9 | |
2.397 | 2.393 | 2.395 | |
2.395 |
General comments (publicly viewable) (Max 1000 characters): PSU-1
Test was verified on 9/22/2026 ✔