Summary for Test 2026-09-22-5-4

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 99999
DEA: 0322222
DIST-CO-RTE-PM03-SAC,OMG-888,99,80-0.6-0.6
Award DateNot set
Closeout DateNot set
Work DescriptionTHIS PROJECT RECORD WAS ADDED FOR DIME TESTERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES.
Location DescriptionTHIS PROJECT RECORD WAS ADDED FOR DIME TESTERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES.
QA Service Level (Verified on 04/05/2013)

Sample Information

Sample Taken Date09/22/2026 Sample Unique Key5
Date that the sample was received by the laboratory/organization performing the testingNot set Sample typeInformational
A brief description of the samplehalf inch HMA sample The quantity of what the sample constitutes200
From where was the sample collectedSource First name of sampler or witnessed byJohn
Last name of sampler or witnessed byDoe Title of sampler
Telephone number of samplerNot set Laboratory sample identification440576256
Linked DIME Sample IDNot set The fabricator/manufacturer/facility nameStonemont Solutions
Transportation Laboratory (TL) NumberNot set Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeRHMA-G
HMA Grading1/2 inch Lot number1
Sublot number2 HMA Mix NumberS25AC6231
Binder content (%)2.4 Virgin binder PGPG 70-10
Design binder PG Binder SupplierValero
RAP content (%)14 WMA Additives
Antistrip type

Test Details

DIME Sample ID: 2026-09-22-5
DIME Test ID: 2026-09-22-5-4
Testing Lab: Stonemont Solutions, Incorporated
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2026-09-22

Test Results


What temperature unit is used?: Celcius
Input Type: Calculated
Tester's full name: John Doe
Date of test: 09/22/2026
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 1468.0 g
Mass Loss: 91.6 g
Correction Factor (Percent by mass of HMA Specimen): 0.35 %
Moisture Content: 0.50 %
Temperature Compensation Factor: 0.61 %
Corrected Asphalt Binder Content: 4.80 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 9/22/2026