Summary for Test 2026-09-08-32-1
Test performed: CTM 670-December 2013Project Information
| Project Identifiers | Project ID: 1000403 DEA: 120K91U4 EFIS: 1222000031 |
|---|---|
| DIST-CO-RTE-PM | 12-ORA-91-R9.2/R11.4 |
| Award Date | 01/03/2025 |
| Closeout Date | Not set |
| Work Description | CONST BRIDGES, RW, SW, PAVEMENT, DRAINAGE AND ELECTRICAL SYSTEMS. |
| Location Description | ORANGE COUNTY IN ANAHEIM FROM 0.9 MILE WEST TO 1.3 MILES EAST OF LAKEVIEW AVENUE OVERCROSSING |
| QA Service Level | 1 (Verified on 08/19/2024) |
Sample Information
| Sample Taken Date | 09/08/2026 | Sample Unique Key | 32 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 09/11/2026 | Sample type | Quality Assurance |
| A brief description of the sample | Double Barrel Zap Screwlok | The quantity of what the sample constitutes | 4 |
| From where was the sample collected | Manufacturer | First name of sampler or witnessed by | David |
| Last name of sampler or witnessed by | Pangle | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | CMC | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Couplers | Production or Authorization Testing | Production Testing |
|---|---|---|---|
| Service or Ultimate | Service | Material Standard Code | ASTM A706 |
| Material Grade | 60 | Rebar Manufacturer | CMC |
| Coupler Manufacturer | BarSplice | Intermediate Assembler or Fabricator | |
| Rebar Size | #6 | Coupler Model | Double Barrel Zap Screwlok |
| Coating Standards | Uncoated | Shape of Rebar | Straight |
| Rebar Hoop Diameter | Rebar Hoop Fabricator | ||
| Coupler Component Heat/Lot Number(s) | 6058 | Rebar Heat Number(s) | 4161037 |
| Rebar Size 2 | Coupler Unique ID | SB-17-02 |
Test Details
DIME Sample ID: 2026-09-08-32
DIME Test ID: 2026-09-08-32-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2026-09-24
Test Results
Number of Samples: 4
Input Type: Measured
Tester's full name: Andrew Auvinen
Date of test: 09/22/2026
UTM: NA
Temperature: 0 f
| Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|
| 1 | 1 | 1 | 6 | 0.44 | 40700 | 92500 | NA | Kleinfelder |
| 2 | 2 | 1 | 6 | 0.44 | 40780 | 92500 | NA | Kleinfelder |
| 3 | 3 | 1 | 6 | 0.44 | 40670 | 92500 | NA | Kleinfelder |
| 4 | 4 | 1 | 6 | 0.44 | 41740 | 95000 | NA | Kleinfelder |
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 9/24/2026 ✔