Summary for Test 2026-09-17-37-1
Test performed: AASHTO T308-10Project Information
| Project Identifiers | Project ID: 1001565 DEA: 030J4404 EFIS: 0319000285 |
|---|---|
| DIST-CO-RTE-PM | 03-BUT-162-15.6/18.5 |
| Award Date | 12/04/2025 |
| Closeout Date | Not set |
| Work Description | COLD PLANE AC PVMT, HMA, MINOR CONCRETE, SIGNAL AND LIGHTING SYSTEM. |
| Location Description | BUTTE COUNTY IN OROVILLE FROM FEATHER RIVER BRIDGE TO FOOTHILL BOULEVARD |
| QA Service Level | 1 (Verified on 09/17/2025) |
Sample Information
| Sample Taken Date | 09/17/2026 | Sample Unique Key | 37 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 09/18/2026 | Sample type | Quality Assurance |
| A brief description of the sample | 1/2" RHMA-O | The quantity of what the sample constitutes | 2 Boxes |
| From where was the sample collected | Source | First name of sampler or witnessed by | Brad |
| Last name of sampler or witnessed by | Mckeehan | Title of sampler | TET |
| Telephone number of sampler | Laboratory sample identification | Daily Sample 26-289 | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Teichert Hallwood | |
| Transportation Laboratory (TL) Number | C955880 | Inspector Lot Number from the Transportation Laboratory (TL) Form | |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | OGFC |
|---|---|---|---|
| HMA Grading | 1/2 inch | Lot number | 1 |
| Sublot number | 7 | HMA Mix Number | 30940542600P |
| Binder content (%) | 7.2 | Virgin binder PG | |
| Design binder PG | PG 64-16 | Binder Supplier | PNW |
| RAP content (%) | 0 | WMA Additives | No |
| Antistrip type |
Test Details
DIME Sample ID: 2026-09-17-37
DIME Test ID: 2026-09-17-37-1
Testing Lab: CT D03 - Olivehurst Northern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2026-09-18
Test Results
What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: Joshua Wilson
Date of test: 09/18/2026
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 1655.5 g
Mass Loss: 124.5 g
Correction Factor (Percent by mass of HMA Specimen): 0.26 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.02 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 7.26 %
General comments (publicly viewable) (Max 1000 characters): L1
OBC 7.2%
Test was verified on 9/18/2026 ✔