Summary for Test 2026-08-07-15-6

Test performed: CTM 521-June 2020

Project Information

Project IdentifiersProject ID: 212900
DEA: 051G6804
EFIS: 0515000063
DIST-CO-RTE-PM05-SLO-101-16.2-20.3
Award DateNot set
Closeout DateNot set
Work DescriptionUS 101 PISMO CONGESTION RELIEF PROJECT
Location DescriptionIN SAN LUIS OBISPO COUNTY IN PSMO BEACH FROM PISMO OVERHEAD TO 0.5 MILE NORTH OF SHELL BEACH ROAD UC
QA Service Level1 (Verified on 09/30/2019)

Sample Information

Sample Taken Date08/07/2026 Sample Unique Key15
Date that the sample was received by the laboratory/organization performing the testing08/08/2026 Sample typeQuality Control
A brief description of the sample4x8 cylinders The quantity of what the sample constitutes5
From where was the sample collectedJob Site First name of sampler or witnessed byBrenda
Last name of sampler or witnessed byAmaya Title of samplerField Technician
Telephone number of sampler Laboratory sample identificationES26-032, Set 1
Linked DIME Sample ID The fabricator/manufacturer/facility nameAlliance Ready Mix Arroyo Grande
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure namePrice St Wall STA 14+81.5 to 15+63
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberES26-032
The truck number from where the sample was collectedLoad 1 The batch plant ticket number from where the sample was collected1
Concrete batch plant The fabricator/manufacturer designation for the sampleSet 1
A detailed description of where the material sample was collectedPrice St Wall STA 14+81.5 to 15+63 Where the material sample would have been placed if not sampled
From Lot No.1 Bag Lot No.1

Test Details

DIME Sample ID: 2026-08-07-15
DIME Test ID: 2026-08-07-15-6
Testing Lab: G3 Quality, Incorporated - Cerritos
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2026-09-18

Test Results


Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Calculated
Tester's full name: Michael Kaus
Date of test: 09/04/2026
Capped in accordance with?: ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1: 4.00 in
Average diameter of cylinder 2: 4.00 in
Average diameter of cylinder 3: 4.00 in
Maximum load on cylinder 1: 61580 lb
Maximum load on cylinder 2: 59300 lb
Maximum load on cylinder 3: 63890 lb
Type of fracture pattern of cylinder 1: 3
Type of fracture pattern of cylinder 2: 3
Type of fracture pattern of cylinder 3: 3
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Correction factor for cylinder 3: 1.00
Age of specimen: 28 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 4900 in^2
Cross sectional area of cylinder 2: 0 in^2
Cross sectional area of cylinder 3: 0 in^2
Compressive strength (to nearest 10 psi): 0 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 9/18/2026 ✔