Summary for Test 2026-08-25-11-5

Test performed: ASTM F606-21

Project Information

Project IdentifiersProject ID: 1002104
DEA: 07369604
EFIS: 0719000376
DIST-CO-RTE-PM07-UNKNOWN--unknown
Award Date02/11/2026
Closeout DateNot set
Work DescriptionNot set
Location DescriptionNot set
QA Service Level1 (Verified on 04/23/2026)

Sample Information

Sample Taken Date08/25/2026 Sample Unique Key11
Date that the sample was received by the laboratory/organization performing the testing09/03/2026 Sample typeQuality Assurance
A brief description of the sample1-1/2" x 5" Hex Bolt The quantity of what the sample constitutes200
From where was the sample collectedFabricator First name of sampler or witnessed byDavid
Last name of sampler or witnessed byAlvarez Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameUniversal Industrial Sales
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)n/a
Heat Number(s)21016920 Nut Mfg. Lot Number(s)n/a
Washer Mfg. Lot Number(s)n/a Bolt SpecificationA325
Bolt Length(s)5" Nut Specificationn/a
Washer Specificationn/a FinishMech. Galvanization
Diameter/Size1-1/2" Bolt Mfg. Lot NumberM6369
Rocap Test Requirement(s)0 Lubricant Requirements(s)0
Washer Inner Diameter(s)0 Bolt Mill SupplierNot set
Nut Mill SupplierNot set Washer Mill SupplierNot set

Test Details

DIME Sample ID: 2026-08-25-11
DIME Test ID: 2026-08-25-11-5
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2026-09-22

Test Results


Number of Bolt Samples: 1
Input Type: Measured
Tester's full name: Andrew Auvinen
Date of test: 09/17/2026
UTM: NA
Temperature: 0 f
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)Wedge Angle (deg)CommentsTested By
11AM63911.519448000TensileKleinfelder

General comments (publicly viewable) (Max 1000 characters):

Test was verified on 9/22/2026 ✔