Summary for Test 2018-05-17-1-4
Test performed: ASTM F606-14aProject Information
Project Identifiers | Project ID: 212354 DEA: 044K8504 EFIS: 0417000378 |
---|---|
DIST-CO-RTE-PM | 04-MRN,MTRN-1-22.8, 22.80 |
Award Date | 06/21/2017 |
Closeout Date | 12/16/2021 |
Work Description | Giacomini Creek Bridge, Construct sheet pile wall, replace culvert |
Location Description | ROUTE 1, AT POSTMILE 22.8, NEAR BOLINAS, AT 0.52 MILES NORTH OF HORSESHOE HILL RD., MARIN COUNTY SLIPOUT, CONSTRUCT SOLDIER PILE WALL |
QA Service Level | 1 (Verified on 05/01/2017) |
Sample Information
Sample Taken Date | 05/17/2018 | Sample Unique Key | 1 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/21/2018 |
Sample type | Quality Assurance | A brief description of the sample | A325 |
The quantity of what the sample constitutes | Unknown | From where was the sample collected | Distributor |
First name of sampler or witnessed by | Scott | Last name of sampler or witnessed by | Leavitt |
Title of sampler | QA Inspector | Telephone number of sampler | 510 590-0116 |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Portland | Transportation Laboratory (TL) Number | Unknown |
Inspector Lot Number from the Transportation Laboratory (TL) Form | S28-110-18 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
---|---|---|---|
Heat Number(s) | 3065481, 171756, | Nut Mfg. Lot Number(s) | 26764-177400 |
Washer Mfg. Lot Number(s) | 0917-632 | Bolt Specification | F3125 |
Bolt Length(s) | 19-1/2 | Nut Specification | A563DH |
Washer Specification | F436 | Finish | HDG |
Diameter/Size | 7/8 | Bolt Mfg. Lot Number | 18571 |
Rocap Test Requirement(s) | No | Lubricant Requirements(s) | Yes |
Test Details
DIME Sample ID: 2018-05-17-1
DIME Test ID: 2018-05-17-1-4
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2018-05-31
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 05/24/2018
UTM: 400KIP
Temperature: 72 F
Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By |
---|---|---|---|---|---|---|---|
1 | 1A | 26764-177400 | 7/8\" | 70436 | 313.32 | Nut Proof Load | Brian |
General comments (publicly viewable) (Max 1000 characters): Nut Proof Load
Test Graph
Source: Partner Data Point FileTest was verified on 5/24/2018 ✔