Summary for Test 2026-08-27-2-7
Test performed: ASTM F606-21Project Information
| Project Identifiers | Project ID: 1001176 DEA: 042Q5204 EFIS: 0419000021 |
|---|---|
| DIST-CO-RTE-PM | 04-SOL-29-0.0/6.0 |
| Award Date | 07/14/2025 |
| Closeout Date | Not set |
| Work Description | HMA PVMT, MOD DRAINAGE, SIGNALS, SIDEWALKS, CURB RAMPS AND LANDSCAPE. |
| Location Description | SOLANO COUNTY IN VALLEJO FROM 0.2 MILE NORTH OF ROUTE 80/ 29 SEPARATION TO NAPA COUNTY LINE |
| QA Service Level | 1 (Verified on 08/14/2025) |
Sample Information
| Sample Taken Date | 08/27/2026 | Sample Unique Key | 2 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 08/31/2026 | Sample type | Quality Assurance |
| A brief description of the sample | F1554 Grade 55 HDG Anchor Bolts | The quantity of what the sample constitutes | 3 of 410 |
| From where was the sample collected | Distributor | First name of sampler or witnessed by | Lorenzo |
| Last name of sampler or witnessed by | Garcia | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Blue Cirlce Corp | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | L115-150-26 | |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | none |
|---|---|---|---|
| Heat Number(s) | 3146016 | Nut Mfg. Lot Number(s) | none |
| Washer Mfg. Lot Number(s) | none | Bolt Specification | F1554 |
| Bolt Length(s) | 6" | Nut Specification | none |
| Washer Specification | none | Finish | Galvanize |
| Diameter/Size | 3/4 | Bolt Mfg. Lot Number | 86779332/146016A434 |
| Rocap Test Requirement(s) | none | Lubricant Requirements(s) | none |
| Washer Inner Diameter(s) | none | Bolt Mill Supplier | Not set |
| Nut Mill Supplier | Not set | Washer Mill Supplier | Not set |
Test Details
DIME Sample ID: 2026-08-27-2
DIME Test ID: 2026-08-27-2-7
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2026-09-21
Test Results
Number of Bolt Samples: 2
Input Type: Measured
Tester's full name: Andrew Auvinen
Date of test: 09/17/2026
UTM: NA
Temperature: 0 f
| Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Wedge Angle (deg) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|
| 1 | 1A | 3146016 | 0.75 | 29800 | 0 | 0 | Tensile | WSP |
| 2 | 1B | 3146016 | 0.75 | 29900 | 0 | 0 | Tensile | WSP |
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 9/21/2026 ✔