Summary for Test 2026-09-01-46-1
Test performed: AASHTO T315-24Project Information
| Project Identifiers | Project ID: 1002657 DEA: 060U6104 EFIS: 0616000052 |
|---|---|
| DIST-CO-RTE-PM | 06-TUL-99-unknown |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Tulare 99 Pumping Plant Repairs |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 09/01/2026 | Sample Unique Key | 46 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 09/14/2026 | Sample type | Quality Assurance |
| A brief description of the sample | 70-10 | The quantity of what the sample constitutes | 1 CAN OF 70-10 |
| From where was the sample collected | Fabricator | First name of sampler or witnessed by | GRIFFITH |
| Last name of sampler or witnessed by | QC | Title of sampler | QC |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | NOT ON TL 101 | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | 754578 | |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Asphalt Binder | Performance Grade | PG 70-10 |
|---|---|---|---|
| Modified | Lot number | ||
| Sublot number | Tank number | ||
| Time of sample | HMA Supplier | NOT ON TL 101 | |
| Certified Asphalt Supplier | San Joaquin Refinery - Bakersfield CA | Multigrade | No |
| Multigrade Type | Asphalt Binder Mix Number | ||
| HMA Type | 3/4" HMA-A R15 | HMA Supplier Mix ID Number | NOT ON TL 101 |
Test Details
DIME Sample ID: 2026-09-01-46
DIME Test ID: 2026-09-01-46-1
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T315-24: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2026-09-18
Test Results
Phase: Original binder
Input Type: Measured
Tester's full name: Raul Cardenas
Date of test: 09/17/2026
Test Gap: 1 mm
Test Frequency: 10.0 rad/s
Strain Amplitude: 12.06 %
Stress Amplitude: 0.148 kPa
Phase Angle (δ) (for the 10 cycles): 89.4 degree
Complex Modulus (G*) (for the 10 measurements): 1.229 kPa
Test Temperature (Specimen 1): 70.0 C
Dynamic Shear, G*/sin(δ): 1.23 kPa
General comments (publicly viewable) (Max 1000 characters): OG
Test was verified on 9/18/2026 ✔