Summary for Test 2026-09-04-1-1
Test performed: CTM 670-December 2013Project Information
| Project Identifiers | Project ID: 1000707 DEA: 041Q5824 EFIS: 0421000263 |
|---|---|
| DIST-CO-RTE-PM | 04-SM-101-0/21.8 |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | REHABILITATE PAVEMENT, UPGRADE SIGNS, GUARDRAIL, AND T |
| Location Description | SAN MATEO COUNTY FROM SAN MATEO COUNTY LINE IN EAST PALO ALTO TO 0.2 MILES NORTH OF COLMA CREEK BRIDGE IN SOUTH SAN FRANCISCO. |
| QA Service Level | 1 (Verified on 01/13/2025) |
Sample Information
| Sample Taken Date | 09/04/2026 | Sample Unique Key | 1 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 09/10/2026 | Sample type | Quality Assurance |
| A brief description of the sample | SL-17-03 ScrewLok type 2 coupler | The quantity of what the sample constitutes | 20 couplers |
| From where was the sample collected | Distributor | First name of sampler or witnessed by | Anton |
| Last name of sampler or witnessed by | Drozdov | Title of sampler | |
| Telephone number of sampler | 925-915-7543 | Laboratory sample identification | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Camblin Steel | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Couplers | Production or Authorization Testing | Production Testing |
|---|---|---|---|
| Service or Ultimate | Service | Material Standard Code | ASTM A706 |
| Material Grade | 60 | Rebar Manufacturer | CMC Steel Arizona |
| Coupler Manufacturer | BarSplice | Intermediate Assembler or Fabricator | |
| Rebar Size | #11 | Coupler Model | Zap Screwlok |
| Coating Standards | Uncoated | Shape of Rebar | Straight |
| Rebar Hoop Diameter | Rebar Hoop Fabricator | ||
| Coupler Component Heat/Lot Number(s) | 4000035449 | Rebar Heat Number(s) | 9013289 |
| Rebar Size 2 | Coupler Unique ID | SL-17-03 |
Test Details
DIME Sample ID: 2026-09-04-1
DIME Test ID: 2026-09-04-1-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Test Release Date: 2026-09-17
Test Results
Number of Samples: 4
Input Type: Measured
Tester's full name: Andrew Auvinen
Date of test: 09/17/2026
UTM: NA
Halo ID: NA
Temperature: 0 f
| Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Slip (inch) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|---|
| 1 | 1 | 1 | 111 | 1.56 | 0.0083 | 148120 | 94949 | NA | Atlas |
| 2 | 2 | 1 | 11 | 1.56 | 0 | 149040 | 95538 | NA | Atlas |
| 3 | 3 | 1 | 11 | 1.56 | 0 | 148150 | 94968 | NA | Atlas |
| 4 | 4 | 1 | 11 | 1.56 | 0 | 148800 | 95385 | NA | Atlas |
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 9/17/2026 ✔