Summary for Test 2026-07-30-107-5

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 1000703
DEA: 11430194
EFIS: 1118000001
DIST-CO-RTE-PM11-SD-15-0.4/R10.2
Award Date04/16/2025
Closeout DateNot set
Work DescriptionCULVERT RESTORATION, TUNNEL CO MONITORING SYSTEM, & ADA RAMP.
Location DescriptionSAN DIEGO COUNTY IN SAN DIEGO FROM 0.2 MILE SOUTH OF ROUTE 5/15 SEPARATION TO 0.4 MILE SOUTH OF ROUTE 52/15 SEPARATION.
QA Service Level1 (Verified on 07/23/2025)

Sample Information

Sample Taken Date07/30/2026 Sample Unique Key107
Date that the sample was received by the laboratory/organization performing the testing07/31/2026 Sample typeProduction Start-Up
A brief description of the sampleReduced PSU The quantity of what the sample constitutes12 boxes
From where was the sample collectedSupplier First name of sampler or witnessed byGerardo
Last name of sampler or witnessed byCordero Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameMM Lakeside
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading1/2 inch Lot number
Sublot number HMA Mix Number21217105 MM
Binder content (%)0.0 Virgin binder PG
Design binder PG Binder Supplier
RAP content (%)0 WMA Additives
Antistrip type

Test Details

DIME Sample ID: 2026-07-30-107
DIME Test ID: 2026-07-30-107-5
Testing Lab: CT D11 - District 11 Materials Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2026-09-18

Test Results


What temperature unit is used?: Celsius
Input Type: Measured
Tester's full name: Daniel Smith
Date of test: 09/10/2026
Test procedure used?: Method A
Mass of the specimen basket assembly: 4049.0 g
Mass of the specimen and specimen basket assembly prior to ignition: 5607.4 g
Mass of HMA Sample prior to ignition: 1558.4 g
Mass Loss: 90.3 g
Mass of aggregate remaining after ignition: 1468.1 g
Correction Factor (Percent by mass of HMA Specimen): 0.05 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.00 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 5.74 %
General comments (publicly viewable) (Max 1000 characters): Complies Used oven 3 - Target 5.25% - Tested 5.74 %

Test was verified on 9/18/2026 ✔