Summary for Test 2026-07-22-96-2

Test performed: AASHTO T240-23

Project Information

Project IdentifiersProject ID: 1000802
DEA: 07346804
EFIS: 0718000079
DIST-CO-RTE-PM07-VEN-232-0.4/R4.1
Award Date02/04/2025
Closeout DateNot set
Work DescriptionCOLD PLANE AND OVERLAY WITH HMA & RHMA.
Location DescriptionVENTURA COUNTY IN AND NEAR OXNARD FROM ROUTE 232/101 SEPARATION TO ROUTE 118
QA Service Level1 (Verified on 01/27/2025)

Sample Information

Sample Taken Date07/22/2026 Sample Unique Key96
Date that the sample was received by the laboratory/organization performing the testing08/20/2026 Sample typeVerification
A brief description of the sampleAsphalt Binder Sample The quantity of what the sample constitutes1can
From where was the sample collectedSource First name of sampler or witnessed byG ZUBIETA
Last name of sampler or witnessed byG ZUBIETA Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameVALCAN-SATICOY
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAsphalt Binder Performance GradePG 64-16
Modified Lot number
Sublot number Tank number
Time of sample HMA Suppliern/a
Certified Asphalt SupplierValero Wilmington Refinery - Wilmington CA MultigradeNo
Multigrade Type Asphalt Binder Mix Number
HMA Typen/a HMA Supplier Mix ID Numbern/a

Test Details

DIME Sample ID: 2026-07-22-96
DIME Test ID: 2026-07-22-96-2
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T240-23: Standard Method of Test for Effect of Heat and Air on a Moving Film of Asphalt Binder (Rolling Thin-Film Oven Test)
Test Release Date: 2026-09-25

Test Results


Is mass change based on one or two containers?: Two
Is mass change correction factor needed?: Yes
Input Type: Measured
Tester's full name: Angelito Villegas
Date of test: 09/16/2026
Any material loss from containers during heating process/testing?: No
Mass of container #1 before test (m1i): 207.818 grams
Mass of container #2 before test (m2i): 207.006 grams
Mass of container #1 after test (m1f): 207.578 grams
Mass of container #2 after test (m2f): 206.750 grams
Mass of empty container #1: 172.827 grams
Mass of empty container #2: 171.927 grams
Mass correction factor: 0.006
Average mass change: -0.702 percent
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 9/25/2026 ✔