Summary for Test 2026-07-22-96-2
Test performed: AASHTO T240-23Project Information
| Project Identifiers | Project ID: 1000802 DEA: 07346804 EFIS: 0718000079 |
|---|---|
| DIST-CO-RTE-PM | 07-VEN-232-0.4/R4.1 |
| Award Date | 02/04/2025 |
| Closeout Date | Not set |
| Work Description | COLD PLANE AND OVERLAY WITH HMA & RHMA. |
| Location Description | VENTURA COUNTY IN AND NEAR OXNARD FROM ROUTE 232/101 SEPARATION TO ROUTE 118 |
| QA Service Level | 1 (Verified on 01/27/2025) |
Sample Information
| Sample Taken Date | 07/22/2026 | Sample Unique Key | 96 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 08/20/2026 | Sample type | Verification |
| A brief description of the sample | Asphalt Binder Sample | The quantity of what the sample constitutes | 1can |
| From where was the sample collected | Source | First name of sampler or witnessed by | G ZUBIETA |
| Last name of sampler or witnessed by | G ZUBIETA | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | VALCAN-SATICOY | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Asphalt Binder | Performance Grade | PG 64-16 |
|---|---|---|---|
| Modified | Lot number | ||
| Sublot number | Tank number | ||
| Time of sample | HMA Supplier | n/a | |
| Certified Asphalt Supplier | Valero Wilmington Refinery - Wilmington CA | Multigrade | No |
| Multigrade Type | Asphalt Binder Mix Number | ||
| HMA Type | n/a | HMA Supplier Mix ID Number | n/a |
Test Details
DIME Sample ID: 2026-07-22-96
DIME Test ID: 2026-07-22-96-2
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T240-23: Standard Method of Test for Effect of Heat and Air on a Moving Film of Asphalt Binder (Rolling Thin-Film Oven Test)
Test Release Date: 2026-09-25
Test Results
Is mass change based on one or two containers?: Two
Is mass change correction factor needed?: Yes
Input Type: Measured
Tester's full name: Angelito Villegas
Date of test: 09/16/2026
Any material loss from containers during heating process/testing?: No
Mass of container #1 before test (m1i): 207.818 grams
Mass of container #2 before test (m2i): 207.006 grams
Mass of container #1 after test (m1f): 207.578 grams
Mass of container #2 after test (m2f): 206.750 grams
Mass of empty container #1: 172.827 grams
Mass of empty container #2: 171.927 grams
Mass correction factor: 0.006
Average mass change: -0.702 percent
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 9/25/2026 ✔