Summary for Test 2026-09-10-3-2

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 1002496
DEA: 031N4204
EFIS: 0325000024
DIST-CO-RTE-PM03-SIE-89-6.2/6.4
Award DateNot set
Closeout DateNot set
Work DescriptionD03 SIERRA RTE 89 (PM 6.2/6.4) NEAR SIERRAVILLE - COLD PLANE ASPHALT, DITCH EXCAVATION, PAINT TRAFFIC STRIPE. CONTRACT 03-1N4204, RE CHRISTOPHER REBOLLO.
Location DescriptionNot set
QA Service Level1 (Verified on 08/11/2026)

Sample Information

Sample Taken Date09/10/2026 Sample Unique Key3
Date that the sample was received by the laboratory/organization performing the testing09/10/2026 Sample typeQuality Assurance
A brief description of the sample3/4 HMA SP R15 PG 64-28 The quantity of what the sample constitutes2 Boxes HMA 140T
From where was the sample collectedManufacturer First name of sampler or witnessed byDustan
Last name of sampler or witnessed byKliethermes Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameTeichert Martis Valley
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) FormL1 SL2
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/4 inch Lot number1
Sublot number2 HMA Mix Number30540732407P
Binder content (%)5.0 Virgin binder PG
Design binder PGPG 64-28 Binder SupplierPNW
RAP content (%)15 WMA Additives
Antistrip type

Test Details

DIME Sample ID: 2026-09-10-3
DIME Test ID: 2026-09-10-3-2
Testing Lab: CT D03 - Olivehurst Northern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2026-09-16

Test Results


What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: Joshua Wilson
Date of test: 09/15/2026
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 2159.3 g
Mass Loss: 120.9 g
Correction Factor (Percent by mass of HMA Specimen): 0.42 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.02 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 5.18 %
General comments (publicly viewable) (Max 1000 characters): L1 OBC 5.2%

Test was verified on 9/16/2026