Summary for Test 2026-08-20-68-7

Test performed: AASHTO T313-2025

Project Information

Project IdentifiersProject ID: 1000802
DEA: 07346804
EFIS: 0718000079
DIST-CO-RTE-PM07-VEN-232-0.4/R4.1
Award Date02/04/2025
Closeout DateNot set
Work DescriptionCOLD PLANE AND OVERLAY WITH HMA & RHMA.
Location DescriptionVENTURA COUNTY IN AND NEAR OXNARD FROM ROUTE 232/101 SEPARATION TO ROUTE 118
QA Service Level1 (Verified on 01/27/2025)

Sample Information

Sample Taken Date08/20/2026 Sample Unique Key68
Date that the sample was received by the laboratory/organization performing the testing08/25/2026 Sample typeVerification
A brief description of the sampleAsphalt Binder Sample The quantity of what the sample constitutes1can
From where was the sample collectedSource First name of sampler or witnessed byTJ -VULCAN QC
Last name of sampler or witnessed byTJ SHIVERS Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameVulcan-Saticoy
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAsphalt Binder Performance GradePG 64-16
Modified Lot number
Sublot number Tank number
Time of sample HMA Suppliern/a
Certified Asphalt SupplierValero Wilmington Refinery - Wilmington CA MultigradeNo
Multigrade Type Asphalt Binder Mix Number
HMA Typen/a HMA Supplier Mix ID Numbern/a

Test Details

DIME Sample ID: 2026-08-20-68
DIME Test ID: 2026-08-20-68-7
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T313-2025: Determining the Flexural Creep Stiffness of Asphalt Binder Using the Bending Beam Rheometer (BBR)
Test Release Date: 2026-09-16

Test Results


Input Type: Calculated
Tester's full name: Sunday Agude
Date of test: 09/15/2026
Paired test specimens performed?: no data
BBR Software for individual test specimens: no data
Maximum test bath temperature at 240 S: 0.0 C
Minimum test bath temperature at 240 S: 0.0 C
Time of test load application: no data
File name of test data: no data
Time test specimen in bath: no data
Time test started: no data
Flags issued by software during test: no data
Correlation coefficients and least square fit R² value: 0.000
Comments: no data
Regression coefficient a: 0.000
Regression coefficient b: 0.000
Regression coefficient c: 0.000
Load at time 0.0: 0.0 mN
Deflection at time 0.0 s: 0.000 µm
Load at time 0.5 s: 0.0 mN
Deflection at time 0.5 s: 0.000 µm
Loading time 8.0 s: 0.0 s
Load at 8.0 s: 0.0 mN
Test specimen deflection 8.0 s: 0.000 µm
Measured Stiffness Modulus 8.0 s: 0.000 MPa
Estimated Stiffness Modulus 8.0 s: 0.000 MPa
Difference between stiffness moduli 8.0 s: 0.00 %
Estimated m-value 8.0 s: 0.000
Loading time 15.0 s: 0.0 s
Load at 15.0 s: 0.0 mN
Test specimen deflection 15.0 s: 0.000 µm
Measured Stiffness Modulus 15.0 s: 0.000 MPa
Estimated Stiffness Modulus 15.0 s: 0.000 MPa
Difference between stiffness moduli 15.0 s: 0.00 %
Estimated m-value 15.0 s: 0.000
Loading time 30.0 s: 0.0 s
Load at 30.0 s: 0.0 mN
Test specimen deflection 30.0 s: 0.000 µm
Measured Stiffness Modulus 30.0 s: 0.000 MPa
Estimated Stiffness Modulus 30.0 s: 0.000 MPa
Difference between stiffness moduli 30.0 s: 0.00 %
Estimated m-value 30.0 s: 0.000
Loading time 60.0 s: 0.0 s
Load at 60.0 s: 0.0 mN
Beam deflection 60.0 s: 0.000 µm
Test specimen deflection 60.0 s: 0.000 µm
Measured Stiffness Modulus 60.0 s: 0.000 MPa
Estimated Stiffness Modulus 60.0 s: 104.424 MPa
Difference between stiffness moduli 60.0 s: 0.00 %
Estimated m-value 60.0 s: 0.414
Loading time 120.0 s: 0.0 s
Load at 120.0 s: 0.0 mN
Test specimen deflection 120.0 s: 0.000 µm
Measured Stiffness Modulus 120.0 s: 0.000 MPa
Estimated Stiffness Modulus 120.0 s: 0.000 MPa
Difference between stiffness moduli 120.0 s: 0.00 %
Estimated m-value 120.0 s: 0.000
Loading time 240.0 s: 0.0 s
Load at 240.0 s: 0.0 mN
Test specimen deflection 240.0 s: 0.000 µm
Measured Stiffness Modulus 240.0 s: 0.000 MPa
Estimated Stiffness Modulus 240.0 s: 0.000 MPa
Difference between stiffness moduli 240.0 s: 0.00 %
Estimated m-value 240.0 s: 0.000
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 9/16/2026 ✔