Summary for Test 2026-08-20-72-4
Test performed: AASHTO T59-22Project Information
| Project Identifiers | Project ID: 1002418 DEA: 070Y5304 EFIS: 0725000120 |
|---|---|
| DIST-CO-RTE-PM | 07-LA-14 -35.5/46.8 |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Not set |
| Location Description | Not set |
| QA Service Level | 1 (Verified on 07/14/2026) |
Sample Information
| Sample Taken Date | 08/20/2026 | Sample Unique Key | 72 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 08/25/2026 | Sample type | Verification |
| A brief description of the sample | PMCQS-1H | The quantity of what the sample constitutes | 2qt, one container |
| From where was the sample collected | Source | First name of sampler or witnessed by | JHONNY |
| Last name of sampler or witnessed by | CONDOVA | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | SOLEDAD | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Asphaltic Emulsion | Emulsion Grade | QS-1h |
|---|---|---|---|
| Lot Number | Not set | Sub Lot | Not set |
| Dilution Percentage Rate | N/A |
Test Details
DIME Sample ID: 2026-08-20-72
DIME Test ID: 2026-08-20-72-4
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T59-22: Standard Method of Test for Emulsified Asphalts (Viscosity (Saybolt Furol) (Sec. 9))
Test Release Date: 2026-10-09
Test Results
Is Correction factor required?: Yes
Input Type: Calculated
Tester's full name: Hussaya Leelakitrungruang
Date of test: 09/15/2026
What temperature wil you be testing Saybolt Furol Viscosity?: 25 C
Certified Saybolt viscosity of the standard (Certified V): 1.0 sec
Efflux time for determination of the correction factor (ETCF1): 1.0 sec
Efflux time (t2) for determination of the correction factor (ETCF2): 1.0 sec
Correction Factor (F): 1.0 sec
Efflux time (ET) for test sample: 22.0 sec
Corrected efflux time as the Saybolt Furol viscosity (Corrected V): 1 sec
Test efflux temperature: 77 F
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 10/9/2026 ✔