Summary for Test 2018-05-17-12-2

Test performed: ASTM A934-13

Project Information

Project IdentifiersProject ID: 211848
DEA: 112T2174
EFIS: 1116000131
DIST-CO-RTE-PM11-SD-5-R37.4 - R46.5
Award Date12/22/2016
Closeout Date05/01/2026
Work Description(Alternative Delivery) CMGC, San Elijo Highway Bridge Replacement. Replace the San Elijo lagoon highway bridge, construct HOV lanes, construct bike and pedestrian trails and bridge, build multi-use facility at Manchester Ave.
Location DescriptionIN SAN DIEGO COUNTY IN SOLANA BEACH AND ENCINITAS FROM 0.1 MILE NORTH OF LOMAS SANTA FE DRIVE OVERCROSSING TO 0.2 MILE SOUTH OF BIRMINGHAM DRIVE OVERCROSSING
QA Service Level1 (Verified on 01/31/2017)

Sample Information

Sample Taken Date05/17/2018 Sample Unique Key12
Date that the sample was received by the laboratory/organization performing the testing05/21/2018 Sample typeQuality Assurance
A brief description of the sample4 Epoxy coated 4 Plain soil nails The quantity of what the sample constitutes10000 feet
From where was the sample collectedManufacturer First name of sampler or witnessed byGreg
Last name of sampler or witnessed byThompson Title of samplerAssociate Steel Inspector
Telephone number of sampler5103767155 Laboratory sample identificationUnknown
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameWilliams Form Engineering
Transportation Laboratory (TL) NumberUnknown Inspector Lot Number from the Transportation Laboratory (TL) FormB904918
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Threaded Bar Production or Authorization TestingProduction Testing
Threaded Bar SpecificationASTM A615 Threaded Bar Grade75
Threaded Bar TypeDeformed Rebar Size8
Nut Specification for Threaded BarNA System ManufacturerWilliams Form
Epoxy Coating ColorPurple Threaded Bar ApplicationSoil Nail
Coating StandardsASTM A934 epoxy Bar Heat Number(s)1002890429, 100890427
Nut Heat Number(s)Unknown Bar Lot NumberUnknown
Nut Lot Number8S3D Coupler Heat Number(s)Unknown
Coupler GradeUnknown

Test Details

DIME Sample ID: 2018-05-17-12
DIME Test ID: 2018-05-17-12-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A934-13: Standard Specification for Epoxy-Coated Prefabricated Steel Reinforcing Bars (Epoxy-Coating)
Test Release Date: 2018-05-31

Test Results


Input Type: Measured
Tester's full name: Fred Saylor
Date of test: 05/22/2018
Lower spec. limit LSL: 10 mils
Upper spec. limit USL: 15 mils
Bar # for First Bar: 1 100890427
Bar # for Second Bar: 2 100890427
First Bar Side 1 mean value: 13.69
First Bar Side 2 mean value: 13.39
Second Bar Side 1 mean value: 14.21
Second Bar Side 2 mean value: 13.94
First Bar Mean: 13.54
Second Bar Mean: 14.08
Total mean value: 13.81
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 5/24/2018 ✔