Summary for Test 2026-09-11-24-1

Test performed: CTM 231-March 2013

Project Information

Project IdentifiersProject ID: 1002508
DEA: 081R4004
EFIS: 0825000058
DIST-CO-RTE-PM08-SBD-210-R32.8
Award DateNot set
Closeout DateNot set
Work DescriptionRTE 210 LUGONIA AVE UNDERCROSSING - SIDEWALK / ADA CURB RAMP / CROSSWALK, REDLANDS, SAN BERNARDINO. CONTRACT 08-1R4004, RE ALAM.
Location DescriptionNot set
QA Service Level1 (Verified on 09/01/2026)

Sample Information

Sample Taken Date09/11/2026 Sample Unique Key24
Date that the sample was received by the laboratory/organization performing the testing09/11/2026 Sample typeAcceptance
A brief description of the sampleRETEST Native Subgrade The quantity of what the sample constitutes20.2 kg
From where was the sample collectedJob Site First name of sampler or witnessed byRobert
Last name of sampler or witnessed byJarquin Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID2026-09-10-5 The fabricator/manufacturer/facility nameCTM 231 TEST LOCATION
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSoil The fabricator's/manufacturer's product name for the sample
The fabricator/manufacturer designation for the sample A detailed description of where the material sample was collectedSidewalk for Lugonia Ave's Undercrossing of SR-210, Sta "A" 112+16 - 117+65
Where the material sample would have been placed if not sampled

Test Details

DIME Sample ID: 2026-09-11-24
DIME Test ID: 2026-09-11-24-1
Testing Lab: CT D08 - Fontana Field Testing Laboratory
Test Method: CTM 231-March 2013: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates Using Nuclear Gages
Test Release Date: 2026-09-14

Test Results


Method Type:: Standard Count
Number of Tests:: 3
Common Test Maximum Used:: No
Input Type: Measured
Tester's full name: Robert Jarquin
Date of test: 09/11/2026
Gage No.: 36647
Test No.: 1
Nuclear By: Robert Jarquin
Non-Bias Plan No.: 8
Depth: 8"
Material No.: no data
Material Type: Structural Backfill
Impact By: Dylan Nault
Standard Count Density: 1757 g/cc
Count or Density 1: 1068 g/cc
Count or Density 2: 1016 g/cc
Count or Density 3: 965 g/cc
Standard Count Moisture: 644 g/cc
Moisture Count 1: 83 g/cc
Moisture Count 2: 76 g/cc
Moisture Count 3: 89 g/cc
Sum of Count or Density: 3049 g/cc
Average of Count or Density: 1016 g/cc
Sum of Moisture Count: 248 g/cc
Average of Moisture Count: 83 g/cc
Count Ratio Density: 0.58
Count Ratio Moisture: 0.13
Calculated Percent Relative Compaction: 96.8 %
Reported Percent Relative Compaction: 97 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 9/14/2026