Summary for Test 2026-09-02-2-1
Test performed: CTM 670-December 2013Project Information
| Project Identifiers | Project ID: 212900 DEA: 051G6804 EFIS: 0515000063 |
|---|---|
| DIST-CO-RTE-PM | 05-SLO-101-16.2-20.3 |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | US 101 PISMO CONGESTION RELIEF PROJECT |
| Location Description | IN SAN LUIS OBISPO COUNTY IN PSMO BEACH FROM PISMO OVERHEAD TO 0.5 MILE NORTH OF SHELL BEACH ROAD UC |
| QA Service Level | 1 (Verified on 09/30/2019) |
Sample Information
| Sample Taken Date | 09/02/2026 | Sample Unique Key | 2 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 09/04/2026 | Sample type | Quality Assurance |
| A brief description of the sample | ASTM A706 #6 x 3' 2" dia. welded hoops | The quantity of what the sample constitutes | 96 hoops |
| From where was the sample collected | Fabricator | First name of sampler or witnessed by | Jacob |
| Last name of sampler or witnessed by | Garcia | Title of sampler | Quality Assurance Inspector |
| Telephone number of sampler | 7606866753 | Laboratory sample identification | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | CMC Rebar San Bernardino | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | L169-135-26 | |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Welded Hoops | Production or Authorization Testing | Production Testing |
|---|---|---|---|
| Service or Ultimate | Ultimate | Rebar Heat Number(s) | 4160266 |
| Hoop Manufacturer Lot Number(s) | Lot 1 | Material Standard Code | ASTM A706 |
| Material Grade | 60 | Rebar Size | #6 |
| Diameter of Hoop | 3'-2" | Epoxy Coated | No |
| Epoxy Coating Color | NA | Rebar Manufacturer | CMC Arizona |
| Welding Company | CMC Rebar San Bernardino | Coating Standards | Uncoated |
| Weld Type | Flash Welded |
Test Details
DIME Sample ID: 2026-09-02-2
DIME Test ID: 2026-09-02-2-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2026-09-14
Test Results
Number of Samples: 4
Input Type: Measured
Tester's full name: Steven Paine
Date of test: 09/14/2026
UTM: NA
Temperature: 0 f
| Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|
| 1 | 1 | 1 | 6 | 0.44 | 45020 | 102000 | ok necking | Kleinfelder |
| 2 | 2 | 1 | 6 | 0.44 | 43710 | 99500 | ok necking | Kleinfelder |
| 3 | 3 | 1 | 6 | 0.44 | 42490 | 96500 | ok necking | Kleinfelder |
| 4 | 4 | 1 | 6 | 0.44 | 43090 | 98000 | ok necking | Kleinfelder |
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 9/14/2026 ✔