Summary for Test 2026-08-17-80-2

Test performed: CTM 521-June 2020

Project Information

Project IdentifiersProject ID: 1001217
DEA: 010J3604
EFIS: 0119000012
DIST-CO-RTE-PM01-HUM-101-R103.3/R103.7
Award Date06/11/2025
Closeout DateNot set
Work DescriptionSTREAM INTAKE, WELL SUMP, AND WATER BACKWASHING SYSTEM WORK.
Location DescriptionHUMBOLDT COUNTY NEAR TRINIDAD FROM SEAWOOD DRIVE UNDERCROSSING TO 0.3 MILE NORTH OF SEAWOOD DRIVE UNDERCROSSING
QA Service Level1 (Verified on 05/05/2025)

Sample Information

Sample Taken Date08/17/2026 Sample Unique Key80
Date that the sample was received by the laboratory/organization performing the testing08/18/2026 Sample typeQuality Assurance
A brief description of the sampleConcrete The quantity of what the sample constitutes2 CY
From where was the sample collectedJob Site First name of sampler or witnessed byKent
Last name of sampler or witnessed byDavidsen Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameEureka Ready Mix
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier04-R001L Structure name
Bid Item3943305

Material Information

Material TypeConcrete The concrete mix design numberE400F
The truck number from where the sample was collected84 The batch plant ticket number from where the sample was collected46074
Concrete batch plantEureka Ready Mix The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedBackwash pump pad Where the material sample would have been placed if not sampledBackwash pump pad
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2026-08-17-80
DIME Test ID: 2026-08-17-80-2
Testing Lab: CT D01 - District 1 Materials Laboratory
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2026-09-14

Test Results


Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Calculated
Tester's full name: Jamie Kelley
Date of test: 09/14/2026
Capped in accordance with?: ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1: 4.00 in
Average diameter of cylinder 2: 4.00 in
Average diameter of cylinder 3: 4.00 in
Maximum load on cylinder 1: 57487 lb
Maximum load on cylinder 2: 58179 lb
Maximum load on cylinder 3: 57510 lb
Type of fracture pattern of cylinder 1: 3
Type of fracture pattern of cylinder 2: 2
Type of fracture pattern of cylinder 3: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Correction factor for cylinder 3: 1.00
Age of specimen: 28 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 12.57 in^2
Cross sectional area of cylinder 2: 12.57 in^2
Cross sectional area of cylinder 3: 12.57 in^2
Compressive strength (to nearest 10 psi): 4590 psi
General comments (publicly viewable) (Max 1000 characters): 9/14/26 28 day break.

Test was verified on 9/14/2026 ✔