Summary for Test 2026-09-02-56-1
Test performed: AASHTO T308-25Project Information
| Project Identifiers | Project ID: 1002458 DEA: 09428604 EFIS: 0925000087 |
|---|---|
| DIST-CO-RTE-PM | 09-UNKNOWN--unknown |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Not set |
| Location Description | Not set |
| QA Service Level | 1 (Verified on 07/23/2026) |
Sample Information
| Sample Taken Date | 09/02/2026 | Sample Unique Key | 56 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 09/08/2026 |
| Sample type | Acceptance | A brief description of the sample | 3/4” PG 64-28M |
| The quantity of what the sample constitutes | 8 Boxes HMA PSU | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | S | Last name of sampler or witnessed by | Stuwart Ahumada (QC) |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | HMA-1 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | Griffith Edmonston-Lebec | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | |
| Sublot number | HMA Mix Number | ||
| Binder content (%) | 0.0 | Virgin binder PG | |
| Design binder PG | Binder Supplier | ||
| RAP content (%) | Not set | WMA Additives | |
| Antistrip type |
Test Details
DIME Sample ID: 2026-09-02-56
DIME Test ID: 2026-09-02-56-1
Testing Lab: CT D09 - Bishop Field Laboratory
Test Method: AASHTO T308-25: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2026-09-11
Test Results
What temperature unit is used?: Celsius
Input Type: Measured
Tester's full name: Derek Carrington
Date of test: 09/09/2026
Test procedure used?: Method A
Mass of the specimen basket assembly: 4283.2 g
Mass of the specimen and specimen basket assembly prior to ignition: 6402.6 g
Mass of HMA Sample prior to ignition: 2119.4 g
Mass Loss: 115.3 g
Mass of aggregate remaining after ignition: 2004.1 g
Correction Factor (Percent by mass of HMA Specimen): 0.78 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.00 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 4.66 %
General comments (publicly viewable) (Max 1000 characters): HMA-1
Test was verified on 9/11/2026 ✔