Summary for Test 2026-08-24-68-3
Test performed: AASHTO T30-19Project Information
| Project Identifiers | Project ID: 1002030 DEA: 020J7604 EFIS: 0219000157 |
|---|---|
| DIST-CO-RTE-PM | 02-TRI-3-67.7/T85.06 |
| Award Date | 02/18/2026 |
| Closeout Date | Not set |
| Work Description | Tangle Blue CAPM |
| Location Description | Not set |
| QA Service Level | 1 (Verified on 04/06/2026) |
Sample Information
| Sample Taken Date | 08/24/2026 | Sample Unique Key | 68 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 08/24/2026 | Sample type | Production Start-Up |
| A brief description of the sample | 2 Bags of RAP | The quantity of what the sample constitutes | Production Start Up Evaluation |
| From where was the sample collected | Manufacturer | First name of sampler or witnessed by | Giuliano |
| Last name of sampler or witnessed by | Giuntoli | Title of sampler | JET |
| Telephone number of sampler | Laboratory sample identification | D80386B | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Tullis Inc. - Northstate Asphalt (Redding CA) | |
| Transportation Laboratory (TL) Number | 845660 | Inspector Lot Number from the Transportation Laboratory (TL) Form | |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Reclaimed Asphalt Pavement | RAP Source | Norhtstate Asphalt |
|---|---|---|---|
| Aggregate Size | Aggregate Source | ||
| RAP Stockpile | Stockpile Size (tons) | ||
| Reclaimed Asphalt Pavement Mix Number |
Combined Gradation Report Information
| Combined Gradation Report Id | Bin Index | Dime Test Id |
|---|---|---|
| 2026-09-9: HMA Aggregates (Size 3/4"): Type A HMA - Continuous Mixing Plant - Sieve Analysis With RAP | 2 | 2026-08-24-68-3 |
Test Details
DIME Sample ID: 2026-08-24-68
DIME Test ID: 2026-08-24-68-3
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T30-19: Standard Method of Test for Mechanical Analysis of Extracted Aggregate (Mechanical Analysis)
Test Release Date: 2026-09-10
Test Results
Does this test use 1/4 sieve?: No
Is an aggregate correction factor used?: Yes
Input Type: Measured
Tester's full name: Dacota Mei
Date of test: 08/31/2026
| Cumulative Mass Retained | Correction Factor | Cumulative Percent Passing | ||||
|---|---|---|---|---|---|---|
| 1545.5 grams | ||||||
| 0.0 grams | 0.0 % | 100 % | ||||
| 0.0 grams | 0.0 % | 100 % | ||||
| 0.0 grams | 0.0 % | 100 % | ||||
| 15.0 grams | 0.0 % | 99 % | ||||
| 149.7 grams | -0.1 % | 90 % | ||||
| 480.5 grams | -1.0 % | 68 % | ||||
| 839.2 grams | -1.0 % | 45 % | ||||
| 1027.7 grams | -0.9 % | 33 % | ||||
| 1168.4 grams | -0.8 % | 24 % | ||||
| 1265.1 grams | -1.2 % | 17 % | ||||
| 1334.5 grams | -0.8 % | 13 % | ||||
| 1383.5 grams | -0.7 % | 10 % | ||||
| 1419.8 grams | -0.6 % | 7.5 % | ||||
| 1421.6 grams | ||||||
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 9/10/2026 ✔