Summary for Test 2026-08-19-64-3
Test performed: AASHTO T209-25Project Information
| Project Identifiers | Project ID: 1001687 DEA: 11430344 EFIS: 1118000104 |
|---|---|
| DIST-CO-RTE-PM | 11-SD-5,54,94,125-Var |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | CULVERTS RESTORATION, RHMA, JPCP, ISR, BARRIER, LANDSCAPE, ELECTRICAL. |
| Location Description | SAN DIEGO COUNTY AT VARIOUS LOCATIONS |
| QA Service Level | 1 (Verified on 02/05/2026) |
Sample Information
| Sample Taken Date | 08/19/2026 | Sample Unique Key | 64 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 07/16/2026 | Sample type | Quality Assurance |
| A brief description of the sample | Plant Sample | The quantity of what the sample constitutes | 4 boxes |
| From where was the sample collected | Supplier | First name of sampler or witnessed by | Gerardo |
| Last name of sampler or witnessed by | Cordero | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | MM Lakeside | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | RHMA-G |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | |
| Sublot number | HMA Mix Number | 23418180T3 | |
| Binder content (%) | 0.0 | Virgin binder PG | |
| Design binder PG | Binder Supplier | ||
| RAP content (%) | 0 | WMA Additives | |
| Antistrip type |
Test Details
DIME Sample ID: 2026-08-19-64
DIME Test ID: 2026-08-19-64-3
Testing Lab: CT D11 - District 11 Materials Laboratory
Test Method: AASHTO T209-25: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2026-09-11
Test Results
Number of Samples: 1
What is the unit of measurement for theoretical density?: US Units
Mass Determination: Air
Input Type: Measured
Tester's full name: Daniel Smith
Date of test: 09/10/2026
Method Performed: Mechanical Agitation - Method A
Mass of container filled with water 1: 7475.6 grams
Mass of oven-dry sample in air for Sample 1: 2555.8 grams
Mass of container filled with the sample and water for Sample 1: 8979.9 grams
Temperature of Water: 77 °F
Specific Gravity for Sample 1: 2.431
Theoretical maximum density at 25°C (77°F): 151.3 lb/ft^3
General comments (publicly viewable) (Max 1000 characters): N/A - Complies Target 2.449 - Tested 2.431 . Within 0.019
Test was verified on 9/11/2026 ✔