Summary for Test 2018-02-01-17-1

Test performed: CTM 214-August 2010

Project Information

Project IdentifiersProject ID: 212952
DEA: 060S4904
EFIS: 0615000050
DIST-CO-RTE-PM06-KIN-5-0.0/9.0
Award Date02/22/2018
Closeout Date10/25/2019
Work DescriptionREPLACE FAILED CONCRETE SLAB PANELS AND RESURFACE WITH HMA.
Location DescriptionKINGS COUNTY NEAR LOST HILLS FROM KERN COUNTY LINE TO 0.9 MILE SOUTH OF EQUIPMENT UNDERCROSSING
QA Service Level1 (Verified on 05/15/2018)

Sample Information

Sample Taken Date02/01/2018 Sample Unique Key17
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/03/2018
Sample typeAnnual Source Testing A brief description of the sample3/8 concrete aggregates
The quantity of what the sample constitutes1 bag From where was the sample collectedSource
First name of sampler or witnessed byD Last name of sampler or witnessed byRuff
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identification18-0070 Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameGranite Coalinga Transportation Laboratory (TL) NumberC813413C
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierNot set
Structure nameNot set Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-10-0005::COALINGA PIT #1
The fabricator's/manufacturer's product name for the sampleUnknown The fabricator/manufacturer designation for the sampleUnknown
The plant numberUnknown A detailed description of where the material sample was collectedStockpile @ Plant
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size3/8 inch
The concrete mix design numberUnknown Lot numberNot set
Sublot numberNot set Aggregate Mix NumberNot set
HMA PayNo

Test Details

DIME Sample ID: 2018-02-01-17
DIME Test ID: 2018-02-01-17-1
Testing Lab: CT HQ - Sacramento Aggregate Testing Laboratory
Test Method: CTM 214-August 2010: Method of Test for Soundness of Aggregates by Use of Sodium Sulfate
Test Release Date: 2018-05-18

Test Results


What size aggregate is being tested?: Coarse Aggregate
Input Type: Calculated
Tester's full name: Phillip Montes
Date of test: 05/18/2018
Percentage Loss of material retained on 2 x 1 ½ in. sieve: no data
Percentage Loss of material retained on 1 ½ x 1 in. sieve: no data
Percentage Loss of material retained on 1 x ¾ in. sieve: no data
Percentage Loss of material retained on ¾ x ½ in. sieve: no data
Percentage Loss of material retained on ½ x ⅜ in. sieve: no data
Percentage Loss of material retained on ⅜ in. x #4 sieve: no data
Percentage Loss of material retained on 2 in. through 1 1/2 in. sieve: no data
Percentage Loss of material retained on 1 in. through 3/4 in. sieve: no data
Percentage Loss of material retained on 3/4 in. through #4 sieve: no data
Weighted Average Percent Loss of Coarse Aggregate: 6.0 %
Batch Soundness Loss of Coarse Aggregate (2 1/2 in maximum): no data
Batch Soundness Loss of Coarse Aggregate (1 1/2 in maximum): no data
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 5/18/2018