Summary for Test 2026-09-03-13-1

Test performed: CTM 521-June 2020

Project Information

Project IdentifiersProject ID: 1001383
DEA: 010P9004
EFIS: 0125000088
DIST-CO-RTE-PM01-HUM-36-19.1/20.1
Award Date03/10/2025
Closeout DateNot set
Work DescriptionREPAIR STORM DAMAGE. REPAIR ROADWAY EMBANKMENT WITH RETAINING WALL
Location DescriptionIN HUMBOLDT COUNTY NEAR BRIDGEVILLE FROM 1.1 TO 0.1 MILE WEST OF VAN DUZEN RIVER BRIDGE.
QA Service Level1 (Verified on 07/11/2025)

Sample Information

Sample Taken Date09/03/2026 Sample Unique Key13
Date that the sample was received by the laboratory/organization performing the testing09/04/2026 Sample typeVerification
A brief description of the samplePCC The quantity of what the sample constitutes100 cy
From where was the sample collectedJob Site First name of sampler or witnessed byMax
Last name of sampler or witnessed byMather Title of sampler
Telephone number of sampler Laboratory sample identificationC0457
Linked DIME Sample ID The fabricator/manufacturer/facility nameMercer Fraser - Fortuna
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberMF CL 1 .40 SLAG AE
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected115755
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedBack of the truck Chute Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2026-09-03-13
DIME Test ID: 2026-09-03-13-1
Testing Lab: CT D01 - District 1 Materials Laboratory
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2026-09-10

Test Results


Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Calculated
Tester's full name: Leif Ayres
Date of test: 09/10/2026
Capped in accordance with?: ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1: 4.00 in
Average diameter of cylinder 2: 4.01 in
Average diameter of cylinder 3: 4.01 in
Maximum load on cylinder 1: 50062 lb
Maximum load on cylinder 2: 47176 lb
Maximum load on cylinder 3: 48156 lb
Type of fracture pattern of cylinder 1: 1
Type of fracture pattern of cylinder 2: 2
Type of fracture pattern of cylinder 3: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Correction factor for cylinder 3: 1.00
Age of specimen: 7 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 12.57 in^2
Cross sectional area of cylinder 2: 12.63 in^2
Cross sectional area of cylinder 3: 12.63 in^2
Compressive strength (to nearest 10 psi): 3840 psi
General comments (publicly viewable) (Max 1000 characters): 9/10/26 7 Day Break

Test was verified on 9/10/2026 ✔