Summary for Test 2026-08-31-17-1

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 1002572
DEA: 061H9704
EFIS: 0625000105
DIST-CO-RTE-PM06-MAD-152-R0.0/15.5
Award DateNot set
Closeout DateNot set
Work DescriptionMADERA COUNTY SLAB REPLACEMENT WITH DIGOUTS ON SR 59, 152. Cold plane AC, remove concrete pavement and place with HMA and RHMA.
Location DescriptionCONSTRUCTION ON STATE HIGHWAY IN MADERA COUNTY NEAR CHOWCHILLA FROM ROUTE 59/152 SEPARATION TO 0.1 MILE WEST OF ROUTE 99/152 SEPARATION.
QA Service Level1 (Verified on 08/31/2026)

Sample Information

Sample Taken Date08/31/2026 Sample Unique Key17
Date that the sample was received by the laboratory/organization performing the testing08/31/2026 Sample typeAcceptance
A brief description of the sample3/4" HMA Type A 12% RAP The quantity of what the sample constitutes0-750 Tons
From where was the sample collectedManufacturer First name of sampler or witnessed byGurjeet
Last name of sampler or witnessed byLitt Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameSanta Fe Aggregate Winton
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/4 inch Lot number1
Sublot number12 HMA Mix Number
Binder content (%)5.1 Virgin binder PGPG 70-10
Design binder PGPG 70-10 Binder SupplierSJR
RAP content (%)12 WMA Additives
Antistrip type

Test Details

DIME Sample ID: 2026-08-31-17
DIME Test ID: 2026-08-31-17-1
Testing Lab: CT D06 - Millbrook Field Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2026-09-10

Test Results


What temperature unit is used?: Celsius
Input Type: Measured
Tester's full name: Tomas Silva
Date of test: 09/02/2026
Test procedure used?: Method A
Mass of the specimen basket assembly: 2925.4 g
Mass of the specimen and specimen basket assembly prior to ignition: 4999.8 g
Mass of HMA Sample prior to ignition: 2074.4 g
Mass Loss: 108.7 g
Mass of aggregate remaining after ignition: 1965.7 g
Correction Factor (Percent by mass of HMA Specimen): 0.40 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.14 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 4.70 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 9/10/2026 ✔