Summary for Test 2026-03-25-68-5

Test performed: CTM 523-May 2020

Project Information

Project IdentifiersProject ID: 1000259
DEA: 050N74V4
EFIS: 0522000043
DIST-CO-RTE-PM05-SB-101-9.2/9.7
Award Date02/08/2024
Closeout DateNot set
Work DescriptionNot set
Location DescriptionFOR CONSTRUCTION ON STATE HIGHWAY IN SANTA BARBARA COUNTY AT MONTECITO FROM 0.2 MILE NORTH OF SHEFFIELD DRIVE UNDERCROSSING TO 0.3 MILE SOUTH OF SAN YSIDRO ROAD OVERCROSSING
QA Service Level1 (Verified on 04/15/2024)

Sample Information

Sample Taken Date03/25/2026 Sample Unique Key68
Date that the sample was received by the laboratory/organization performing the testing03/25/2026 Sample typeQuality Assurance
A brief description of the sampleCRCP Concrete Sample The quantity of what the sample constitutes450 CY
From where was the sample collectedSupplier First name of sampler or witnessed byJesse
Last name of sampler or witnessed byGomez Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameGranite Padaro Concrete Plant
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design number386
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected18686
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedDischarge from concrete truck into wheelbarrow. Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2026-03-25-68
DIME Test ID: 2026-03-25-68-5
Testing Lab: CT D05 - Carpinteria Field Laboratory
Test Method: CTM 523-May 2020: Method of Test for Flexural Strength of Concrete
Test Release Date: 2026-09-09

Test Results


Number of specimens: 2
Unit system used?: US Units
Does the testing machine measure load or stress on the beam specimen?: Load
Fracture initiates in the tension surface: Within the Middle Third of the Span Length
Is a beam dimensional correction factor used?: No
Input Type: Measured
Tester's full name: Michael Bennett
Date of test: 04/02/2026
Identification number: 0
Width of specimen: 6.0 inch
Width of specimen 2: 6.0 inch
Depth of specimen: 6.1 inch
Depth of specimen 2: 6.1 inch
Span length of specimen: 18 inch
Span length of specimen 2: 18 inch
Maximum load applied: 7310 lb
Maximum load applied 2: 7380 lb
Curing history and apparent moisture condition of the specimen: water bath
If specimen was capped, ground or if leather shims were used: leather shims
Defects in specimen: 0
Age of specimen: 8 days
Age of specimen in hours: 0 hours
Modulus of rupture: 605 psi
Modulus of rupture 2: 610 psi
Modulus of rupture average: 610 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 9/9/2026 ✔