Summary for Test 2026-08-05-93-1
Test performed: CTM 227-December 2014Project Information
| Project Identifiers | Project ID: 1001612 DEA: 051P2104 EFIS: 0521000188 |
|---|---|
| DIST-CO-RTE-PM | 05-MON,-1-44.3 |
| Award Date | 12/19/2025 |
| Closeout Date | Not set |
| Work Description | CONSTRUCT SOLDIER PILE WALL AND STRUCTURAL CONCRETE BARRIER SLAB. |
| Location Description | MONTEREY COUNTY NEAR BIG SUR ABOUT 1.1 MILES SOUTH OF PFEIFFER CANYON BRIDGE |
| QA Service Level | 1 (Verified on 11/03/2025) |
Sample Information
| Sample Taken Date | 08/05/2026 | Sample Unique Key | 93 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 08/05/2026 | Sample type | Quality Control |
| A brief description of the sample | 1/2" Aggregate | The quantity of what the sample constitutes | 10 CY |
| From where was the sample collected | Manufacturer | First name of sampler or witnessed by | Edward |
| Last name of sampler or witnessed by | Carrillo | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Graniterock Seaside/Sand city | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-35-0012 |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
| The plant number | A detailed description of where the material sample was collected | graniterock seaside batchplant | |
| Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 1/2 inch | |
| The concrete mix design number | Lot number | ||
| Sublot number | Aggregate Mix Number |
Test Details
DIME Sample ID: 2026-08-05-93
DIME Test ID: 2026-08-05-93-1
Testing Lab: Pacific Crest Engineering, Incorporated
Test Method: CTM 227-December 2014: Method of Test for Evaluating Cleanness of Coarse Aggregate (Cleanness)
Test Release Date: 2026-09-08
Test Results
Describe the gradation of the aggregate or the test method:: Mix of sizes - max 1.5 in.
Input Type: Calculated
Tester's full name: Robert Cruz
Date of test: 08/14/2026
Cleanness value (11/2 in. maximum aggregate mix): 85
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 9/8/2026 ✔