Summary for Test 2026-09-05-13-4
Test performed: CTM 202-November 2011Project Information
| Project Identifiers | Project ID: 1001645 DEA: 051R1004 EFIS: 0523000125 |
|---|---|
| DIST-CO-RTE-PM | 05-SLO, -1-32.6 |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | BRIDGE REPLACEMENT, HMA, AND RSP PROTECTION. |
| Location Description | SAN LUIS OBISPO COUNTY NEAR MORRO BAY AT TORO CREEK BRIDGE |
| QA Service Level | 1 (Verified on 11/03/2025) |
Sample Information
| Sample Taken Date | 09/05/2026 | Sample Unique Key | 13 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 09/08/2026 | Sample type | Acceptance |
| A brief description of the sample | 752RN1810 Aggregate | The quantity of what the sample constitutes | 9/5/26 - 752RN1810 |
| From where was the sample collected | Manufacturer | First name of sampler or witnessed by | GeoSolutions QC |
| Last name of sampler or witnessed by | GeoSolutions QC | Title of sampler | QC |
| Telephone number of sampler | Laboratory sample identification | 260905-1 752RN1810 | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | CalPortland - San Luis Obispo | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-40-0013 |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
| The plant number | A detailed description of where the material sample was collected | Stockpile @ plant | |
| Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 1 inch | |
| The concrete mix design number | 752RN1810 | Lot number | |
| Sublot number | Aggregate Mix Number |
Test Details
DIME Sample ID: 2026-09-05-13
DIME Test ID: 2026-09-05-13-4
Testing Lab: CT D05 - Paso Robles Field Laboratory
Test Method: CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2026-09-08
Test Results
What size aggregate is being tested?: Fine Aggregate
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
For Combined Gradation only, has the fine aggregate sample been reduced?: No
For Combined Gradation only, use #40 Sieve?: No
Input Type: Measured
Tester's full name: Kyle Engen
Date of test: 09/08/2026
| Sieve Size | Cumulative Mass Retained | Cumulative Percent Passing | ||||
|---|---|---|---|---|---|---|
| 492.6 grams | ||||||
| 0.0 grams | 100 % | |||||
| 11.3 grams | 98 % | |||||
| 70.7 grams | 86 % | |||||
| 141.8 grams | 71 % | |||||
| 251.0 grams | 49 % | |||||
| 388.1 grams | 21 % | |||||
| 461.9 grams | 6 % | |||||
| 481.9 grams | 2 % | |||||
| 481.9 grams | ||||||
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 9/8/2026 ✔