Summary for Test 2026-07-23-86-6
Test performed: CTM 389-19Project Information
| Project Identifiers | Project ID: 66667 DEA: JMFPP EFIS: 0019000043 |
|---|---|
| DIST-CO-RTE-PM | 59--- |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Special project for submitting Sample information for JMF Prequalification Program. |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 07/23/2026 | Sample Unique Key | 86 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 07/23/2026 | Sample type | Verification |
| A brief description of the sample | JMFR | The quantity of what the sample constitutes | 12 boxes |
| From where was the sample collected | Supplier | First name of sampler or witnessed by | Gerardo |
| Last name of sampler or witnessed by | Cordero | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Pyramid Construction - Heber | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | |
| Sublot number | HMA Mix Number | SP 2024 | |
| Binder content (%) | 0.0 | Virgin binder PG | |
| Design binder PG | Binder Supplier | Valero | |
| RAP content (%) | 0 | WMA Additives | No |
| Antistrip type |
Test Details
DIME Sample ID: 2026-07-23-86
DIME Test ID: 2026-07-23-86-6
Testing Lab: CT D11 - District 11 Materials Laboratory
Test Method: CTM 389-19: Method of Test for Hamburg Wheel-Track Testing of Compacted Hot Mix Asphalt
Test Release Date: 2026-09-10
Test Results
Specified number of passes at 12.7 mm: 20000
Specimen Preparation Method: PMLC
Input Type: Measured
Tester's full name: Daniel Smith
Date of test: 09/08/2026
Test Temperature: 131 F
Compaction Method: SGC Cylindrical Specimen
Air Void Content for specimen A-1: 7.1 %
Air Void Content for specimen A-2: 7.3 %
Air Void Content for specimen B-1: 7.0 %
Air Void Content for specimen B-2: 6.8 %
Stripping Inflection Point (Wheel A): >20000
Stripping Inflection Point (Wheel B): >20000
Maximum impression at 5000 passes (left wheel): 0.9 mm
Maximum impression at 5000 passes (right wheel): 1.25 mm
Average impression at 5000 passes (left/right avg): 1.08 mm
Maximum impression at 10000 passes (left wheel): 1.25 mm
Maximum impression at 10000 passes (right wheel): 1.5 mm
Average impression at 10000 passes (left/right avg): 1.38 mm
Maximum impression at 15000 passes (left wheel): 1.57 mm
Maximum impression at 15000 passes (right wheel): 1.74 mm
Average impression at 15000 passes (left/right avg): 1.66 mm
Maximum impression at 20000 passes (left wheel): 1.82 mm
Maximum impression at 20000 passes (right wheel): 1.98 mm
Average impression at 20000 passes (left/right avg): 1.9 mm
Maximum impression at 25000 passes (left wheel): no data
Maximum impression at 25000 passes (right wheel): no data
Average impression at 25000 passes (left/right avg): no data
Raw Data: excel
General comments (publicly viewable) (Max 1000 characters): Complies Target <12.7 mm - Tested an Avg of 1.88 mm
Test was verified on 9/10/2026 ✔