Summary for Test 2026-08-20-68-5

Test performed: AASHTO T316-22

Project Information

Project IdentifiersProject ID: 1000802
DEA: 07346804
EFIS: 0718000079
DIST-CO-RTE-PM07-VEN-232-0.4/R4.1
Award Date02/04/2025
Closeout DateNot set
Work DescriptionCOLD PLANE AND OVERLAY WITH HMA & RHMA.
Location DescriptionVENTURA COUNTY IN AND NEAR OXNARD FROM ROUTE 232/101 SEPARATION TO ROUTE 118
QA Service Level1 (Verified on 01/27/2025)

Sample Information

Sample Taken Date08/20/2026 Sample Unique Key68
Date that the sample was received by the laboratory/organization performing the testing08/25/2026 Sample typeVerification
A brief description of the sampleAsphalt Binder Sample The quantity of what the sample constitutes1can
From where was the sample collectedSource First name of sampler or witnessed byTJ -VULCAN QC
Last name of sampler or witnessed byTJ SHIVERS Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameVulcan-Saticoy
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAsphalt Binder Performance GradePG 64-16
Modified Lot number
Sublot number Tank number
Time of sample HMA Suppliern/a
Certified Asphalt SupplierValero Wilmington Refinery - Wilmington CA MultigradeNo
Multigrade Type Asphalt Binder Mix Number
HMA Typen/a HMA Supplier Mix ID Numbern/a

Test Details

DIME Sample ID: 2026-08-20-68
DIME Test ID: 2026-08-20-68-5
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T316-22: Standard Method of Test for Viscosity Determination of Asphalt Binder Using Rotational Viscometer
Test Release Date: 2026-09-10

Test Results


Is viscosity reading in cP/Pa-s?: Pa-s
Input Type: Measured
Tester's full name: Hussaya Leelakitrungruang
Date of test: 09/08/2026
Time of test: 9:38 HH:MM
Test Temperature: 135.0 C
Speed: 100 rpm
Spindle size: 21 in
Torque: 71.2 %
Viscosity reading #1 (A) : 0.353 Pa-s
Viscosity reading #2 (B) : 0.354 Pa-s
Viscosity reading #3 (C): 0.361 Pa-s
Average viscosity: 0.356 Pa-s
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 9/10/2026 ✔