Summary for Test 2026-08-24-4-1
Test performed: CTM 670-December 2013Project Information
| Project Identifiers | Project ID: 1001194 DEA: 051H4404 EFIS: 0516000074 |
|---|---|
| DIST-CO-RTE-PM | 05-SB,SLO-1-50.3/50.6,0.0/0.3 |
| Award Date | 09/30/2025 |
| Closeout Date | Not set |
| Work Description | SANTA MARIA RIVER BRIDGE (REPLACE). |
| Location Description | SANTA BARBARA AND SAN LUIS OBISPO COUNTIES IN AND NEAR GUADALUPE AT SANTA MARIA RIVER BRIDGE |
| QA Service Level | 1 (Verified on 06/02/2025) |
Sample Information
| Sample Taken Date | 08/24/2026 | Sample Unique Key | 4 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 08/27/2026 | Sample type | Quality Assurance |
| A brief description of the sample | Flash Welded Rebar Hoops | The quantity of what the sample constitutes | 8 of Lots 1 and 5 |
| From where was the sample collected | Fabricator | First name of sampler or witnessed by | Lorenzo |
| Last name of sampler or witnessed by | Garcia | Title of sampler | QA |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | TNT Rebar Nucor | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | L115-148-26 | |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Welded Hoops | Production or Authorization Testing | Production Testing |
|---|---|---|---|
| Service or Ultimate | Ultimate | Rebar Heat Number(s) | 4100000897 |
| Hoop Manufacturer Lot Number(s) | Lots 1 thru 5 | Material Standard Code | ASTM A706 |
| Material Grade | 60 | Rebar Size | #6 |
| Diameter of Hoop | 2'-6" | Epoxy Coated | No |
| Epoxy Coating Color | NA | Rebar Manufacturer | Nucor |
| Welding Company | TNT Rebar Company | Coating Standards | Uncoated |
| Weld Type | Flash Welded |
Test Details
DIME Sample ID: 2026-08-24-4
DIME Test ID: 2026-08-24-4-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2026-09-08
Test Results
Number of Samples: 8
Input Type: Measured
Tester's full name: Andrew Auvinen
Date of test: 09/08/2026
UTM: NA
Temperature: 0 f
| Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|
| 1 | 1 | 1 | 6 | 0.44 | 44930 | 102000 | Affected Zone | Kleinfelder |
| 2 | 2 | 1 | 6 | 0.44 | 42760 | 97000 | Okay Necking | Kleinfelder |
| 3 | 3 | 1 | 6 | 0.44 | 42540 | 96500 | Okay Necking | Kleinfelder |
| 4 | 4 | 1 | 6 | 0.44 | 42920 | 97500 | Okay Necking | Kleinfelder |
| 5 | 1 | 5 | 6 | 0.44 | 42390 | 96500 | Okay Necking | Kleinfelder |
| 6 | 2 | 5 | 6 | 0.44 | 40930 | 93000 | Okay Necking | Kleinfelder |
| 7 | 3 | 5 | 6 | 0.44 | 42530 | 96500 | Okay Necking | Kleinfelder |
| 8 | 4 | 5 | 6 | 0.44 | 41200 | 95500 | Okay Necking | Kleinfelder |
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 9/8/2026 ✔