Summary for Test 2026-09-01-30-1
Test performed: ASTM D36-14ε1Project Information
| Project Identifiers | Project ID: 1001308 DEA: 081L1804 EFIS: 0819000162 |
|---|---|
| DIST-CO-RTE-PM | 08-RIV-91-13.5/16.8 |
| Award Date | 10/20/2025 |
| Closeout Date | Not set |
| Work Description | JPCP (RSC), INDIVIDUAL SLAB REPLACEMENT (RSC) & RUBBERIZED HMA. |
| Location Description | RIVERSIDE COUNTY IN RIVERSIDE FROM 0.6 MILE WEST OF VAN BUREN BOULEVARD OVERCROSSING TO 0.2 MILE EAST OF MADISON STREET UNDERCROSSING. |
| QA Service Level | 1 (Verified on 06/24/2025) |
Sample Information
| Sample Taken Date | 09/01/2026 | Sample Unique Key | 30 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 09/02/2026 | Sample type | Verification |
| A brief description of the sample | Asphalt Rubber Binder | The quantity of what the sample constitutes | 1can |
| From where was the sample collected | Source | First name of sampler or witnessed by | Drew |
| Last name of sampler or witnessed by | Drew QC | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Vulcan Corona | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Asphalt Rubber Binder | Asphalt modifier supplier | |
|---|---|---|---|
| Performance Grade | PG 64-16 | Lot number | |
| Sublot number | Asphalt Rubber Binder Mix Number |
Test Details
DIME Sample ID: 2026-09-01-30
DIME Test ID: 2026-09-01-30-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM D36-14ε1: Standard Test Method for Softening Point of Bitumen (Ring-and-Ball Apparatus) (Softening Point)
Test Release Date: 2026-09-08
Test Results
ASTM Thermometer used?: C
Input Type: Measured
Tester's full name: Angelito Villegas
Date of test: 09/04/2026
Softening Point Sample 1: 61 C
Softening Point Sample 2: 61 C
Bath Liquid: freshly boiled distilled water
Minutes Reaction: no data
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 9/8/2026 ✔