Summary for Test 2026-08-26-40-3

Test performed: ASTM D5329-16

Project Information

Project IdentifiersProject ID: 1002490
DEA: 042X7404
EFIS: 0425000147
DIST-CO-RTE-PM04-SCL--unknown
Award DateNot set
Closeout DateNot set
Work DescriptionCOLD PLANE, HMA(TYPE A), RHMA(OGFC) & HIGH
Location DescriptionIn SANTA CLARA COUNTY NEAR LOS GATOS FROM SANTA CLARA COUNTY LINE TO 0.1 MILE NORTH OF HEBARD ROAD
QA Service Level1 (Verified on 09/15/2026)

Sample Information

Sample Taken Date08/26/2026 Sample Unique Key40
Date that the sample was received by the laboratory/organization performing the testing09/03/2026 Sample typeProduction Start-Up
A brief description of the sample2 CANS OF RUBBER BINDER The quantity of what the sample constitutes2, 1 QUART CANS
From where was the sample collectedManufacturer First name of sampler or witnessed byFERNANDO
Last name of sampler or witnessed byVEGA Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameMARTIN MURIETTA- SUNOL
Transportation Laboratory (TL) NumberSJ-082626-1 Inspector Lot Number from the Transportation Laboratory (TL) FormSJ-082626-1
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAsphalt Rubber Binder Asphalt modifier supplierAlbina Chowchilla
Performance GradePG 64-16 Lot number
Sublot number Asphalt Rubber Binder Mix Number

Test Details

DIME Sample ID: 2026-08-26-40
DIME Test ID: 2026-08-26-40-3
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: ASTM D5329-16: Standard Test Methods for Sealants and Fillers, Hot-Applied, for Joints and Cracks in Asphalt Pavements and Portland Cement Concrete Pavements (Asphalt Pavement)
Test Release Date: 2026-09-04

Test Results


Input Type: Measured
Tester's full name: Erik Svensson
Date of test: 09/04/2026
Temperature: 25 C
Ball Penetration (P1): 1 mm
Final Dial reading (F1): 56 mm
Ball Penetration (P2): 1 mm
Final Dial reading (F2): 55 mm
Ball Penetration (P3): 0 mm
Final Dial reading (F3): 55 mm
Resilience 1: 45 %
Resilience 2: 46 %
Resilience 3: 45 %
Average Resilience: 45 %
Minutes Reaction: no data
General comments (publicly viewable) (Max 1000 characters): RESILIENSE REBOUND

Test was verified on 9/4/2026 ✔