Summary for Test 2026-08-18-82-5

Test performed: AASHTO T316-22

Project Information

Project IdentifiersProject ID: 1000888
DEA: 07346304
EFIS: 0718000073
DIST-CO-RTE-PM07-LA-101-7.9/11.8
Award Date04/28/2025
Closeout DateNot set
Work DescriptionINSTALL RUBBERIZED HOT MIXED ASPHALT.
Location DescriptionLOS ANGELES COUNTY IN THE CITY AND COUNTY OF LOS ANGELES FROM 0.1 MILE SOUTH OF PILGRIMAGE OVERCROSSING TO ROUTE 101/170 SEPARATION.
QA Service Level1 (Verified on 07/16/2025)

Sample Information

Sample Taken Date08/18/2026 Sample Unique Key82
Date that the sample was received by the laboratory/organization performing the testing08/24/2026 Sample typeVerification
A brief description of the sampleAsphalt Binder Sample The quantity of what the sample constitutes1can
From where was the sample collectedSource First name of sampler or witnessed byVICTOR
Last name of sampler or witnessed byPham Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameAAA-Irwindale
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAsphalt Binder Performance GradePG 64-16
Modified Lot number
Sublot number Tank number
Time of sample HMA Suppliern/a
Certified Asphalt SupplierSan Joaquin Refinery - Bakersfield CA MultigradeNo
Multigrade Type Asphalt Binder Mix Number
HMA Typen/a HMA Supplier Mix ID Numbern/a

Test Details

DIME Sample ID: 2026-08-18-82
DIME Test ID: 2026-08-18-82-5
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T316-22: Standard Method of Test for Viscosity Determination of Asphalt Binder Using Rotational Viscometer
Test Release Date: 2026-09-04

Test Results


Is viscosity reading in cP/Pa-s?: Pa-s
Input Type: Measured
Tester's full name: David Valenzuela
Date of test: 09/03/2026
Time of test: 8:20 HH:MM
Test Temperature: 135.0 C
Speed: 100 rpm
Spindle size: 21 in
Torque: 56.9 %
Viscosity reading #1 (A) : 0.28 Pa-s
Viscosity reading #2 (B) : 0.287 Pa-s
Viscosity reading #3 (C): 0.286 Pa-s
Average viscosity: 0.284 Pa-s
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 9/4/2026 ✔