Summary for Test 2026-04-10-63-1
Test performed: CTM 226-July 2010Project Information
| Project Identifiers | Project ID: 1001201 DEA: 120S5304 EFIS: 1220000087 |
|---|---|
| DIST-CO-RTE-PM | 12-ORA-57-15.9 |
| Award Date | 09/05/2025 |
| Closeout Date | Not set |
| Work Description | PLACE JPCP (RSC) AND HMA, MODIFY RAMP AND ELECTRICAL SYSTEMS. |
| Location Description | ORANGE COUNTY IN ANAHEIM AT SOUTHBOUND ROUTE 57 OFF-RAMP TO WESTBOUND ROUTE 91 |
| QA Service Level | 1 (Verified on 05/05/2025) |
Sample Information
| Sample Taken Date | 04/10/2026 | Sample Unique Key | 63 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 04/10/2026 | Sample type | Quality Control |
| A brief description of the sample | CIP aggregates | The quantity of what the sample constitutes | 1 per batch |
| From where was the sample collected | Supplier | First name of sampler or witnessed by | Joseph |
| Last name of sampler or witnessed by | Hermosillo | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Associated Ready Mix - Fountain Valley | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-19-0025 |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
| The plant number | A detailed description of where the material sample was collected | stockpile or belt cut | |
| Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 1 inch | |
| The concrete mix design number | 556300 | Lot number | |
| Sublot number | Aggregate Mix Number |
Test Details
DIME Sample ID: 2026-04-10-63
DIME Test ID: 2026-04-10-63-1
Testing Lab: Sequoia Consultants
Test Method: CTM 226-July 2010: Method of Test for Determination of Moisture Content of Soils and Aggregates by Oven Drying
Test Release Date: 2026-09-03
Test Results
Input Type: Calculated
Tester's full name: Jeffrey Lopez
Date of test: 04/14/2026
Wet weight of the sample: 1000.0000000000 grams
Dry weight of the sample: 938.0000000000 grams
Weight of water in sample: 62.0000000000 grams
Percent moisture: 6.2 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 9/3/2026 ✔