Summary for Test 2026-07-22-84-4

Test performed: AASHTO T269-14

Project Information

Project IdentifiersProject ID: 1000697
DEA: 021J75U4
EFIS: 0224000092
DIST-CO-RTE-PM02-LAS-36-14.4/R16.8
Award Date01/23/2025
Closeout DateNot set
Work DescriptionPLACE HMA AND CLASS 2 AB, EXCAVATE ROADWAY, & INSTALL LIGHTING SYSTEM.
Location DescriptionLASSEN COUNTY ABOUT 9 MILES WEST OF SUSANVILLE FROM 1.3 MILES WEST TO 1.2 MILES EAST OF WILLARD CREEK ROAD
QA Service Level1 (Verified on 10/24/2024)

Sample Information

Sample Taken Date07/22/2026 Sample Unique Key84
Date that the sample was received by the laboratory/organization performing the testing07/22/2026 Sample typeProduction Start-Up
A brief description of the sample16 boxes of Lime Treated 3/4-inch Type A HMA (eq. PG 64-28) with 22.0% RAP and virgin PG 58-34 from Albina (K-Falls, Or) The quantity of what the sample constitutesProduction Start Up Evaluation
From where was the sample collectedManufacturer First name of sampler or witnessed byDawn
Last name of sampler or witnessed bySloatermen Title of sampler
Telephone number of sampler Laboratory sample identificationD80302
Linked DIME Sample ID The fabricator/manufacturer/facility nameHat Creek Construction and Materials - Ward Lake Plant (Litchfield, CA)
Transportation Laboratory (TL) Number845878 Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/4 inch Lot number
Sublot number HMA Mix Number
Binder content (%)5.7 Virgin binder PGPG 64-28
Design binder PG Binder SupplierAlbina (Klamath Falls, OR)
RAP content (%)22 WMA Additives
Antistrip type1.0% Lime

Test Details

DIME Sample ID: 2026-07-22-84
DIME Test ID: 2026-07-22-84-4
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Test Release Date: 2026-09-03

Test Results


Number of tests: 3
Is the sample lab compacted or field compacted?: Lab compacted
Input Type: Measured
Tester's full name: Josh Ferency
Date of test: 07/24/2026
123
2.379 2.375 2.371
2.473

3.8 %

4.0 %

4.1 %

4.0 %
General comments (publicly viewable) (Max 1000 characters): AASHTO T 269: Pa=4.0% Allowed tolerance for air voids is 2.5 – 5.5%

Test was verified on 9/3/2026 ✔