Summary for Test 2026-07-29-75-4

Test performed: AASHTO T269-14

Project Information

Project IdentifiersProject ID: 1000513
DEA: 020J8504
EFIS: 0219000168
DIST-CO-RTE-PM02-SIS-89-21/R34.622
Award Date08/05/2025
Closeout DateNot set
Work DescriptionMCCLOUD CAPM - PAVEMENT REHABILITATION
Location DescriptionIN SISKIYOU COUNTY AT AND NEAR MCCLOUD FROM 0.1 MILE SOUTH OF MUD CREEK BRIDGE TO ROUTE 5
QA Service Level1 (Verified on 08/12/2024)

Sample Information

Sample Taken Date07/29/2026 Sample Unique Key75
Date that the sample was received by the laboratory/organization performing the testing07/27/2026 Sample typeProduction Start-Up
A brief description of the sample16 boxes of Lime Treated 1/2-inch Type A HMA (eq. PG 64-16) with 25.0% RAP and PG 58-22 from Albina - K-Falls, Or. The quantity of what the sample constitutesProduction Start Up Evaluation
From where was the sample collectedManufacturer First name of sampler or witnessed byJoe
Last name of sampler or witnessed byDelgado Title of samplerConsultant Tester
Telephone number of sampler Laboratory sample identificationD80316
Linked DIME Sample ID The fabricator/manufacturer/facility nameTullis Inc. - Northstate Asphalt (Redding CA)
Transportation Laboratory (TL) Number846266 Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading1/2 inch Lot number
Sublot number HMA Mix Number
Binder content (%)4.6 Virgin binder PGPG 64-16
Design binder PGPG 58-22 Binder SupplierAlbina (Klamath Falls, OR)
RAP content (%)24 WMA Additives
Antistrip type1.0% Lime

Test Details

DIME Sample ID: 2026-07-29-75
DIME Test ID: 2026-07-29-75-4
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Test Release Date: 2026-09-03

Test Results


Number of tests: 3
Is the sample lab compacted or field compacted?: Lab compacted
Input Type: Measured
Tester's full name: Josh Ferency
Date of test: 07/31/2026
123
2.417 2.410 2.404
2.506

3.6 %

3.8 %

4.1 %

3.8 %
General comments (publicly viewable) (Max 1000 characters): AASHTO T 269: Pa=3.8% Allowed tolerance for air voids is 2.5 – 5.5%

Test was verified on 9/3/2026 ✔