Summary for Test 2026-08-21-34-1
Test performed: ASTM A882-20Project Information
| Project Identifiers | Project ID: 1000710 DEA: 100P9244 EFIS: 1023000226 |
|---|---|
| DIST-CO-RTE-PM | 10-MPA-140-42.0/42.7 |
| Award Date | 08/22/2025 |
| Closeout Date | Not set |
| Work Description | Fergusen Slide Rock Avalanche Shed |
| Location Description | Mariposa County, along Route 140 in the Merced River canyon, about 8 miles east of Briceburg and 7.6 miles west of El Portal. |
| QA Service Level | 1 (Verified on 10/15/2024) |
Sample Information
| Sample Taken Date | 08/21/2026 | Sample Unique Key | 34 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 08/28/2026 | Sample type | Quality Assurance |
| A brief description of the sample | ASTM A882 | The quantity of what the sample constitutes | 1 |
| From where was the sample collected | Manufacturer | First name of sampler or witnessed by | EDWARD |
| Last name of sampler or witnessed by | LEACH | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Sumiden Wire | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM4 - Prestressing Strand | Comments | |
|---|---|---|---|
| Reel/Coil/Pack Number(s) | T350163-6-1 | Number of Coils | 1 |
| Group Number | Strand Diameter | .6 in | |
| Grade | 270 | Strand Specification | ASTM A 882 |
| Heat Number(s) | T0243142 | Mfg. Lot Number(s) | n/a |
| Manufacturer(s) | Sumiden Wire |
Test Details
DIME Sample ID: 2026-08-21-34
DIME Test ID: 2026-08-21-34-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A882-20: Standard Specification for Filled Epoxy-Coated Seven-Wire Prestressing Steel Strand (Withdrawn 2019) (Coating Adhesion)
Test Release Date: 2026-09-14
Test Results
Input Type: Calculated
Tester's full name: Andrew Auvinen
Date of test: 09/03/2026
Coating Adhesion Pass/Fail: Pass
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 9/14/2026 ✔