Summary for Test 2026-08-10-78-3

Test performed: AASHTO T315-24

Project Information

Project IdentifiersProject ID: 209698
DEA: 072332E4
EFIS: 0700000391
COOP: 0705187
DIST-CO-RTE-PM07-LA-I-5-45.4/54
Award Date07/01/2021
Closeout DateNot set
Work DescriptionAddition of 14 miles of HOV lanes in both directions would extend existing carpool lanes on the I- 5 in San Fernando Valley to Santa Clarita Valley
Location DescriptionThe I-5 North Capacity Enhancements Project focuses on improvements to the I-5 freeway from cities of Santa Clarita and Castaic, beginning at the SR-14 interchange to Parker Rd.
QA Service Level2 (Verified on 02/03/2021)

Sample Information

Sample Taken Date08/10/2026 Sample Unique Key78
Date that the sample was received by the laboratory/organization performing the testing08/19/2026 Sample typeVerification
A brief description of the sampleAsphalt Binder Sample The quantity of what the sample constitutes1can
From where was the sample collectedSource First name of sampler or witnessed byChristopher
Last name of sampler or witnessed byHurtado Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameVulcan Sun Valley - Blvd.
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAsphalt Binder Performance GradePG 64-16
Modified Lot number
Sublot number Tank number
Time of sample HMA Suppliern/a
Certified Asphalt SupplierValero Wilmington Refinery - Wilmington CA MultigradeNo
Multigrade Type Asphalt Binder Mix Number
HMA Typen/a HMA Supplier Mix ID Numbern/a

Test Details

DIME Sample ID: 2026-08-10-78
DIME Test ID: 2026-08-10-78-3
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T315-24: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2026-09-02

Test Results


Phase: Original binder
Input Type: Calculated
Tester's full name: Sunday Agude
Date of test: 09/02/2026
Phase Angle (δ) (for the 10 cycles): 86.2 degree
Dynamic Shear, G*/sin(δ): 1.35 kPa
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 9/2/2026