Summary for Test 2026-07-14-110-2
Test performed: AASHTO T308-10Project Information
| Project Identifiers | Project ID: 1000513 DEA: 020J8504 EFIS: 0219000168 |
|---|---|
| DIST-CO-RTE-PM | 02-SIS-89-21/R34.622 |
| Award Date | 08/05/2025 |
| Closeout Date | Not set |
| Work Description | MCCLOUD CAPM - PAVEMENT REHABILITATION |
| Location Description | IN SISKIYOU COUNTY AT AND NEAR MCCLOUD FROM 0.1 MILE SOUTH OF MUD CREEK BRIDGE TO ROUTE 5 |
| QA Service Level | 1 (Verified on 08/12/2024) |
Sample Information
| Sample Taken Date | 07/14/2026 | Sample Unique Key | 110 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 07/14/2026 | Sample type | Acceptance |
| A brief description of the sample | 16 boxes of Lime Treated 1/2-inch RHMA-G (PG 64-16 CR) virgin PG 64-16 from Valero – Benicia | The quantity of what the sample constitutes | 750 Tons |
| From where was the sample collected | Manufacturer | First name of sampler or witnessed by | Joe |
| Last name of sampler or witnessed by | Delgado | Title of sampler | Consultant |
| Telephone number of sampler | Laboratory sample identification | D80282 | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Tullis Inc. - Northstate Asphalt (Redding CA) | |
| Transportation Laboratory (TL) Number | 846251 | Inspector Lot Number from the Transportation Laboratory (TL) Form | |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | RHMA-G |
|---|---|---|---|
| HMA Grading | 1/2 inch | Lot number | |
| Sublot number | HMA Mix Number | ||
| Binder content (%) | 7.6 | Virgin binder PG | PG 58-22 |
| Design binder PG | PG 58-22 | Binder Supplier | Albina (Klamath Falls, OR) |
| RAP content (%) | 0 | WMA Additives | No |
| Antistrip type | 1.0% Lime |
Test Details
DIME Sample ID: 2026-07-14-110
DIME Test ID: 2026-07-14-110-2
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2026-09-02
Test Results
What temperature unit is used?: Celsius
Input Type: Measured
Tester's full name: Sean McWithey
Date of test: 08/17/2026
Test procedure used?: Method A
Mass of the specimen basket assembly: 3035.4 g
Mass of the specimen and specimen basket assembly prior to ignition: 4648.5 g
Mass of HMA Sample prior to ignition: 1613.1 g
Mass Loss: 129.0 g
Mass of aggregate remaining after ignition: 1484.1 g
Correction Factor (Percent by mass of HMA Specimen): 0.32 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.19 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 7.49 %
General comments (publicly viewable) (Max 1000 characters): Pb=7.49%, Target: 7.4-8.3%
Test was verified on 9/2/2026 ✔