Summary for Test 2026-08-24-55-1
Test performed: AASHTO T308-10Project Information
| Project Identifiers | Project ID: 1002024 DEA: 044AC704 EFIS: 0420000148 |
|---|---|
| DIST-CO-RTE-PM | 04-MRN-101-8/15.3 |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | PAVEMENT - Repaving from Nellen to Miller Creek |
| Location Description | Not set |
| QA Service Level | 1 (Verified on 04/06/2026) |
Sample Information
| Sample Taken Date | 08/24/2026 | Sample Unique Key | 55 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 08/24/2026 | Sample type | Acceptance |
| A brief description of the sample | 1/2 RHMA-O | The quantity of what the sample constitutes | 750 tons |
| From where was the sample collected | Source | First name of sampler or witnessed by | Ignacio |
| Last name of sampler or witnessed by | Arechiga | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Dutra rRichmond | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | OGFC |
|---|---|---|---|
| HMA Grading | 1/2 inch | Lot number | |
| Sublot number | HMA Mix Number | ||
| Binder content (%) | 0.0 | Virgin binder PG | |
| Design binder PG | Binder Supplier | ||
| RAP content (%) | Not set | WMA Additives | |
| Antistrip type |
Test Details
DIME Sample ID: 2026-08-24-55
DIME Test ID: 2026-08-24-55-1
Testing Lab: CT D04 - Richmond Field Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2026-09-02
Test Results
What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: casey farrington
Date of test: 08/24/2026
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 1539.8 g
Mass Loss: 98.6 g
Correction Factor (Percent by mass of HMA Specimen): 0.82 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.19 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 5.39 %
General comments (publicly viewable) (Max 1000 characters): L1-SL1 PSU
Test was verified on 9/2/2026 ✔